H365--Medical Gas Annual Inspection Services for the OKC VA Medical Center and Lawton/Ft.Sill

Inactive on SAM.gov — responses were due 26 Aug 2026 · Unrestricted (full and open) · Department of Veterans Affairs (VA) · NAICS 541350 · Solicitation 36C25926Q0722

Following NAICS 541350? Get new solicitations in it by email as they post — no account needed.

Email me new ones

A newer version of this notice has been posted. SAM.gov republished solicitation 36C25926Q0722 on 19 August 2026. This page is kept because it is a real record, but the current requirement, dates and attachments are on the latest version. Read the latest version →

What happened next

SAM.gov marked this notice inactive — responses were due 26 August 2026.

No award notice on SAM.gov yet. Not every award is posted there, so this does not mean it went unawarded.

Email me when the award is announced. One email, when SAM.gov posts the award notice. Not every award is posted there; if none appears within six months we'll tell you and stop. No account needed.

Solicitation details

Solicitation number36C25926Q0722
Notice ID27430cddca094de098419a0a1e92ce12
AgencyDepartment of Veterans Affairs (VA)
Contracting officeNETWORK CONTRACT OFFICE 19 (36C259)
NAICS code541350 — Building Inspection Services
Product / service code (PSC)H365
Set-asideUnrestricted (full and open)
Notice typeSolicitation
Posted19 August 2026
Response deadline26 August 2026 (closed)

Get new NAICS 541350 solicitations by email

This one has closed. We'll email you when new NAICS 541350 (Building Inspection Services) solicitations post — the first email lists what is open right now, then at most once a week, only when something new posts. No account needed; unsubscribe in a click.

Description

Please provide the current estimated quantities, by facility, for medical-gas outlets/inlets, zone valve boxes, area alarm panels, master alarm panels, manifolds, medical-air compressors, vacuum pumps, dental compressors/vacuum systems, emergency oxygen supply connections, bulk tanks, oxygen concentrators, dew-point monitors, and CO monitors. I have provided previous years inspection report to assist with inventory. If a complete equipment inventory is unavailable, will the VA provide drawings, prior inspection reports, existing inventories, equipment lists, or other available records for quotation purposes, notwithstanding that the awarded contractor must physically validate the initial digital inventory? A new inventory must be completed by contractor; I will attach a copy of our latest annual inspection. Please confirm whether the annual requirement to inspect all outlets for leakage, flow, damage, and wear may be distributed throughout each 12-month performance period, as stated in the SOW, and whether the contractor may coordinate multiple scheduled visits to accomplish that work. Previously these tasks have been completed in one visit or multiple visits close together to limit disruptions to the facility, our team will work with the contractor to maximize their time on station. Please clarify the requirement stating that the general contractor (not agents thereof) must have an on-site representative whenever contractor personnel are performing work. May a qualified employee of the prime contractor serve in this role while certified subcontractor technicians perform specialized testing? Must that representative hold any of the listed ASSE credentials? If the only task being performed is the inspection the only requirement is for the inspector to have the appropriate certifications this action would not require the prime to hold the credentials, the intent is to ensure no breakdown in communication between VA and Prime. Please confirm whether one individual may satisfy multiple required ASSE credential categories, provided the individual holds each active certification needed for the work performed, or whether separate technicians are required for ASSE 6005, 6010, 6020, 6030, 6035, and 6040. One individual may satisfy multiple ASSE credential categories, but there are limitations.. you cant perform work and certify your own work , again the work being performed would dictate the requirement. Please confirm whether all six listed ASSE credentials must be present on-site for every recurring visit, or only when the specific task requiring that credential is performed. Only when required by the tasks being performed.(for inspection/inventory only NO) The SOW period-of-performance dates on page 7 contain apparent option-year end-date errors. May offerors rely on the corrected periods shown in the Price/Cost Schedule on pages 13 14: Base Year 9/1/2026 8/31/2027 and four successive 12-month option periods through 8/31/2031? A: Dates are tentative and subject to change based on the date of contract award so they will reflect inaccuracies until award is finalized. Please make offers based on base plus 4 OY rates. The solicitation includes performance at Oklahoma City VA Medical Center and Lawton North VA Clinic, but the attached wage determination identifies Comanche and Cotton Counties. Will the VA issue or identify the applicable wage determination for Oklahoma County, or confirm which wage determination applies to each performance location? A: This will be corrected with the Answer submission amendment. Please identify the anticipated invoice frequency under Section B.1, which marks Other but does not state whether invoicing is monthly, per completed service event, or another interval. A: At the discretion of the COR after winning bidder chosen, at minimum monthly Please confirm whether replacement parts, filters, belts, calibration gases, repair labor, and corrective maintenance are excluded from the firm-fixed-price inspection scope unless separately authorized by written contract modification. That is correct, typically staff at our facility perform corrective actions, in the event repairs would be beyond their capabilities the VA would seek quotes for the repairs. Please confirm whether the optional six-month extension under FAR 52.217-8 should be separately priced with the quotation. If so, please provide the required pricing format or confirm that one-half of Option Year 4 s annual price is acceptable. A: No, as per FAR 52.217-8, should the situation arise that this option should be invoked, the pricing would follow the pricing of the last year Option Year of the Contract (Example, if 1 yr is $5,000, 6 months will be per regulation $2,500. We are interested in proposing on this project but after looking through the soliciation attachments, I did not see any preproposal walk through. Are you planning on having one? If so, can you please provide the date/time? A: I would suggest that we move forward without a site visit, as this has not been needed in the past and I feel that we have supplied plenty of information for contractor s to use. Please confirm that offerors must submit only the completed SF 1449 page 1, completed Price Schedule, signed VAAR 852.219-75 certification, technical capability information, ASSE credential evidence, and relevant-experience information, with no separate formal proposal required A: Confirmed, that is correct. To ensure that we can accurately evaluate the scope of work and prepare appropriate pricing, we would greatly appreciate the following information for each performance location: I have provided a copy of the report from last year to assist with inventory, the requirement clearly states (The contractor shall provide a comprehensive digital medical gas system inventory on a Microsoft Excel format for the Oklahoma City VA Medical Center outlining/listing the information below. This comprehensive digital outlet inventory will be based on field gathered data and information from physical validation of equipment (i.e., not based upon existing facility documentation). Total number of medical gas and vacuum outlets, preferably broken down by gas type. Total number of zone valve boxes. Total number of area alarm panels and master alarm panels. Quantity, manufacturer, model, and capacity of the medical air compressors and vacuum pumps. Quantity and configuration of the manifold systems. Information regarding the bulk oxygen system/tank, including the system configuration and capacity. Confirmation as to whether replacement of filters or other preventive-maintenance parts is included in the contractor s scope, or whether the contractor is only required to inspect, test, and report recommended maintenance. If replacement parts are included, please provide the applicable filter/part numbers, sizes, quantities, and required replacement frequencies. Bed count, operating room count, ICU count, and other major clinical-area counts for the Oklahoma City Medical Center, if available. Confirmation as to whether zone valves are required to undergo functional testing in addition to being inventoried. The Statement of Work identifies the required inspection, testing, calibration, certification, and inventory activities; however, the above quantities and equipment details do not appear to be provided. I have provided a copy of the report from last year to assist with inventory, the requirement clearly states (The contractor shall provide a comprehensive digital medical gas system inventory on a Microsoft Excel format for the Oklahoma City VA Medical Center outlining/listing the information below. This comprehensive digital outlet inventory will be based on field gathered data and information from physical validation of equipment (i.e., not based upon existing facility documentation). We would greatly appreciate any available equipment inventories, drawings, previous inspection reports, or other documentation that may assist prospective contractors in accurately determining the scope of the requirement. . I have provided a copy of the report from last year to assist with inventory, the requirement clearly states (The contractor shall provide a comprehensive digital medical gas system inventory on a Microsoft Excel format for the Oklahoma City VA Medical Center outlining/listing the information below. This comprehensive digital outlet inventory will be based on field gathered data and information from physical validation of equipment (i.e., not based upon existing facility documentation). Estimated Inventory: Does the VA have an existing inventory or estimated quantity of the medical gas outlets and other major system components covered under the scope? If available, could the Government provide an estimated outlet count and/or existing inventory for offerors to use as a pricing reference? We understand that the contractor is still required to perform field verification and develop the final digital inventory…

Version history

SAM.gov has posted 4 notices under solicitation 36C25926Q0722, oldest first.

Documents in the solicitation package

3 files are attached to this notice.

  • VAMC Oklahoma City - Annual Medical Gas Inspection SEPT 2025 JDa 02.docx
  • 36C25926Q0722 0001.docx
  • 36C25926Q0722.docx

Download all 3 files as one ZIPFree account, no credit card.

Reading them for requirements? FedSift turns the package into a compliance matrix — every requirement with the page it came from, exportable to Excel.

Or download them one at a time from SAM.gov.

Go deeper on this solicitation

FedSift reads the full solicitation package — every attachment — and pre-extracts the compliance matrix, evaluation factors, key risks, win themes and deal-breakers, each with a verbatim quote and the exact PDF page it came from. It scores the opportunity against your company profile, tells you whether to bid as prime or sub, and ranks teaming partners who could close your gaps.

Open the AI analysis in FedSift →

Free forever plan — no credit card. Browse solicitations without an account; sign in for AI analysis and matching.

Market context: VA and NAICS 541350

About the buyer and the industry, not this specific solicitation. Source: USASpending.gov award data, updated nightly.

  • In fiscal year 2026, VA obligated $3.8M across 81 contract actions under NAICS 541350.
  • 47 contracts worth $7.4M in this category end within the next 18 months.

VA contracts under NAICS 541350 →

Other open solicitations in NAICS 541350

All NAICS 541350 solicitations →

More from Department of Veterans Affairs

All VA solicitations →

Source: this notice on SAM.gov. FedSift republishes public federal procurement data and is not affiliated with the U.S. Government. Always confirm dates and requirements against SAM.gov before responding.

FedSift turns SAM.gov and USASpending data into federal BD intelligence — smart matches, recompete radar, cited AI solicitation analysis and compliance matrices.

Source data: SAM.gov (solicitations) and USASpending.gov (awards), refreshed nightly. FedSift is not affiliated with the U.S. Government.

Pricing · Privacy · Terms · support@fedsift.app