Bldg. 1025 HVAC at Kirtland AFB

Inactive on SAM.gov · 8(a) Sole Source (FAR 19.8) · Department of the Army, DoD · Kirtland AFB, NM · NAICS 238220 · Solicitation W912PP26QA045

Following NAICS 238220? Get new solicitations in it by email as they post — no account needed.

Email me new ones

What happened next

This is SAM.gov's award notice for this solicitation.

Awarded to COLT BUILDERS INC Des Moines NM 88418 USA for $207K, posted 29 September 2026.

Solicitation details

Solicitation numberW912PP26QA045
Notice ID40af08092fb74ec19f2255df1ca9efb6
AgencyDepartment of Defense (DoD)
Sub-agencyDepartment of the Army
Contracting officeW075 ENDIST ALBUQUERQUE
NAICS code238220 — Plumbing, Heating, and Air-Conditioning Contractors
Product / service code (PSC)Y1NZ
Set-aside8(a) Sole Source (FAR 19.8)
Notice typeAward Notice
Posted29 September 2026
Response deadlineNot stated
Place of performanceKirtland AFB, NM, USA
CompetitionLikely sole source (FedSift estimate from the notice text) — confirm on SAM.gov before investing in a bid

Get new NAICS 238220 solicitations by email

This one has closed. We'll email you when new NAICS 238220 (Plumbing, Heating, and Air-Conditioning Contractors) solicitations post — the first email lists what is open right now, then at most once a week, only when something new posts. No account needed; unsubscribe in a click.

Description

This action was awarded as an 8(a) Sole Source Set-Aside under the authority of section 8(a) of the Small Business Act. The contractor shall furnish all parts, material, labor, equipment and supervision necessary to complete the work for Building 1025 HVAC. Construction Contractor to provide and install an 8.5 x20.5 duct hood over the air compressor heat exhausts that transition to 14 round duct. Duct hood must be detachable to allow for the removal of the compressor top plate for maintenance. Contractor to remove SF-1 and wall louver. Expand existing 12 x18 wall penetration to 18 x18 penetration on the South wall. Install wall mounted exhaust fan rated for 1500 CFM @ 1 W.C. with using single phase 208V with soft start motor. Fan and motor must be rated to handle 140 F exhaust air. Provide 18 x18 ducted exhaust plenum 2 into the mechanical room. Route 14 duct from each compressor into the 18 x18 plenum. Utilize conical fittings for branch take-offs and 30 minimum rectangular to round transitions and 1.5D round elbows. Provide gasketed low leakage motorized control dampers on each 14 duct between the hood and the exhaust plenum. Contractor to provide a 3-ton (36,000 BTU/hr) wall mounted mini split air conditioning unit on west wall above the compressed air desiccant driers. Mount wall mounted unit on available space without moving existing compressed air piping or conduit. Secure unit to wall per manufacturer instructions. Route condensate to nearest floor sink. Terminate condensate pipe above floor sink rim. Size per manufacturer requirements. Contractor to provide mini split condensing unit with high ambient kit by the same manufacturer. Locate exterior unit between stairs to electrical room and mechanical room. Secure unit to the ground per manufacturer instructions or mounted on C-channel with concrete anchors. Mini split must be 208V single phase. Contractor to provide and install refrigerant line sets between mini split per manufacturer instructions. Flash and seal new penetration for line set. Provide controls for equipment as follows: Exhaust fan must start when either compressor activates. Fan must remain on for at least 5 minutes (adjustable up to at least 15 minutes) after compressor turns off. Motorized control dampers must open when associated air compressor is activated. Damper must stay open until the exhaust fan turns off. Provide duct access panel for each damper on the bottom of the duct. Provide thermostat for new mini split. Set temperature to 85 F (adjustable). All new duct and duct connections shall be sealed to Class A and hung from the structure or mechanical room walls (where allowed) per SMACNA HVAC Duct Construction Standards. Provide 1in. W.C. Duct Pressure Classification on all exhaust duct systems, provide a minimum 22 Ga. Galvanized sheet metal meeting ASTM A924/A924M and ASTM A653/653M for all exhaust duct as indicated on the supplemental drawings. Provide power to the new exhaust fan and motorized control dampers from Panel P1. Reuse of conduit from demolished supply fan is acceptable provided it meets all NEC requirements. Provide power to mini split air conditioner from panel LM1. All wiring must be provided per NEC. Provide disconnects to exhaust fan, condensing unit and indoor unit per UFC 3-410-01. Contractor will need to be escorted at all times with the construction schedule coordinated with the facility user. All new penetrations between the electrical and mechanical rooms must be sealed with fire caulk. The North and East walls in the Mechanical Room cannot have any new penetration or be utilized to mount hang or hang any new equipment.

Go deeper on this solicitation

FedSift reads the full solicitation package — every attachment — and pre-extracts the compliance matrix, evaluation factors, key risks, win themes and deal-breakers, each with a verbatim quote and the exact PDF page it came from. It scores the opportunity against your company profile, tells you whether to bid as prime or sub, and ranks teaming partners who could close your gaps.

Open the AI analysis in FedSift →

Free forever plan — no credit card. Browse solicitations without an account; sign in for AI analysis and matching.

Market context: DoD and NAICS 238220

About the buyer and the industry, not this specific solicitation. Source: USASpending.gov award data, updated nightly.

  • In fiscal year 2026, DoD obligated $337.8M across 644 contract actions under NAICS 238220.
  • 236 contracts worth $391.7M in this category end within the next 18 months.

DoD contracts under NAICS 238220 →

Other open solicitations in NAICS 238220

All NAICS 238220 solicitations →

More from Department of Defense

All DoD solicitations →

Source: this notice on SAM.gov. FedSift republishes public federal procurement data and is not affiliated with the U.S. Government. Always confirm dates and requirements against SAM.gov before responding.

FedSift turns SAM.gov and USASpending data into federal BD intelligence — smart matches, recompete radar, cited AI solicitation analysis and compliance matrices.

Source data: SAM.gov (solicitations) and USASpending.gov (awards), refreshed nightly. FedSift is not affiliated with the U.S. Government.

Pricing · Privacy · Terms · support@fedsift.app