FedSift

SolicitationsVETERANS AFFAIRS, DEPARTMENT OFNAICS 334516

6515--Thyroid Uptake System

VETERANS AFFAIRS, DEPARTMENT OF · Solicitation 36C26026Q0928 · NAICS 334516 · Unrestricted (full and open) · Closed

Solicitation details

Solicitation number36C26026Q0928
Notice ID50ba2fc1a0f34a808cb420aebcbe3aa7
AgencyVETERANS AFFAIRS, DEPARTMENT OF
Sub-tierVETERANS AFFAIRS, DEPARTMENT OF
Contracting office260-NETWORK CONTRACT OFFICE 20 (36C260)
NAICS code334516
Product / service code (PSC)6515
Set-asideUnrestricted (full and open)
Notice typeSources Sought
Posted06 August 2026
Response deadline13 August 2026 (closed)
Place of performanceSpokane

Description

SOURCES SOUGHT NOTICE THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR PROPOSAL OR QUOTE; THE VA IS NOT SEEKING PRICING OR OFFERS. The Department of Veterans Affairs, VISN 20, in support of the Mann-Grandstaff VA Medical Center, is performing market research to compile data regarding: (1) The availability and capability of qualified small business concerns; (2) Identify if there are sufficient number of qualified Service-Disabled Veteran-Owned Small Business, Veteran Owned Small Business, HUB Zone 8(a), Women-Owned Small Business, or Small Disadvantaged Business, Small Business concerns relative to the subject North American Industry Classification System (NAICS) code. Responses to the information requested will assist the Government in determining the appropriate procurement method, including any set-aside decision. Respondents should clearly describe their capabilities to include management experience, equipment and personnel or the ability to obtain them. Furthermore, interested sources must also meet all requirements of Federal, State, and Local Municipal codes regarding operations of this type of service. The NAICS code assigned is: 334516 Analytical Laboratory Instrument Manufacturing The small business size standard is 1,000 employees. Not responding to this Sources Sought does not preclude participation in any future or potential solicitation, or Request for Quotation. It is the intent of the Mann-Grandstaff VA Medical Center to use the information gathered for market research purposes only. If a formal solicitation is released, it will be posted via the Contract Opportunies on Sam.gov. DESCRIPTION OF THE REQUIREMENT: The Department of Veterans Affairs, Network Contracting Office 20, is seeking sources that can provide a Captus 4000e or equal thyroid uptake system. Equal product will be considered if it has the same characteristics as listed below: 1. General System Functionality Must be a comprehensive nuclear medicine measurement system capable of performing thyroid uptake measurements, wipe tests, bioassay measurements, and automated quality assurance functions. Must include a software-driven workflow that supports predefined protocols and customizable measurement sequences. 2. User Interface & Computer Requirements Must utilize a color touch screen user interface with a large-format display (minimum 20 inches for visibility during procedures). Must operate on a current, widely supported Windows OS platform. (VA current platform Windows 10 or 11) Must support generation of reports containing graphics, isotope spectra, and archived data, with ability to save or print reports in PDF format. 3. Detector & Measurement Specifications Thyroid Uptake Detector Must utilize a NaI(Tl) scintillation detector capable of precise uptake measurements. (Spec: 2 inch diameter NaI(Tl).) Must include a collimator meeting recognized nuclear medicine performance standards (e.g., ANSI or IAEA). Must include a physical measurement/alignment mechanism to ensure consistent detector to thyroid distance. Multichannel Analyzer (MCA) Must include an MCA with a minimum of 1024 channels. Must provide automated and manual calibration capabilities. Must support user defined and preset ROIs, live time, real time, and total count presets. Must support accurate count rate linearity ( 2% deviation up to at least 150,000 cps). Optional Well Counter Must support well counting for capsule/liquid dose formats utilizing a NaI(Tl) well detector. (Spec: 2 inch diameter NaI(Tl).) Must provide shielding sufficient for radiation safety and measurement accuracy (minimum 1 inch lead shielding). 4. Quality Assurance Capabilities Must provide fully automated QA tests including energy calibration, zero adjust, gain adjust, detector efficiency, resolution, chi square, constancy, and minimum detectable activity (MDA). Must include both automated and manual calibration options. 5. Thyroid Uptake Measurement Requirements Must support capsule and liquid dose formats. Must allow pre-dose and pre count measurement. Must include multiple predefined thyroid uptake protocols and allow custom protocol creation. 6. Wipe Test & Bioassay Capabilities Must support multi group wipe test setup and isotope identification with spectral display. Must flag wipe test results exceeding trigger levels. Must support bioassay monitoring for common isotopes (e.g., I 123, I 125, I 131). Must allow user defined action levels and produce individual and summary reports. 7. Connectivity / System Integration Requirements Must provide optional or integrated DICOM capability that can retrieve patient data and upload reports to hospital information systems. 8. Physical / Form Factor Requirements Must include a mobile, ergonomic stand with adjustable height and articulating detector arm capable of wide range motion (vertical travel and rotation). Must include secure storage for neck phantom and quality control sources. Must include cable management to maintain safe, clinical grade setup. Must include hospital-grade power configuration with isolation transformer. 9. Reporting & Data Archival Requirements Must allow reporting that includes full spectrum graphics and thyroid uptake time vs value graphs. Must permit archiving of measurement data and export in standard formats. The information above is intended to be descriptive, not restrictive, to indicate the quality of equipment that will be satisfactory. It is the responsibility of the interested source to demonstrate to the Government that the interested source can provide equipment that fulfills the required specifications. POTENTIAL SOURCES SHALL PROVIDE THE FOLLOWING INFORMATION IN THEIR RESPONSE: Mark if your firm is eligible for participation in one of the following small business programs. If so, please indicate the program: [ ] yes [ ] no - Small Business (SB) [ ] yes [ ] no - HUBZone [ ] yes [ ] no - Small Business 8(a) [ ] yes [ ] no - Small Disadvantaged Business (SDB) [ ] yes [ ] no - Women-Owned (WO) Small Business [ ] yes [ ] no - Service Disabled Veteran Owned Small Business (SDVOSB) [ ] yes [ ] no - Veteran Owned Small Business (VOSB) [ ] yes [ ] no - Large Business [ ] yes [ ] no - Other (please specify) [ ] yes [ ] no Are you the Original Equipment Manufacturer (OEM)? [ ] yes [ ] no If not the OEM, are you an authorized distributor, and can produce a letter from the OEM? [ ] yes [ ] no Is this product available on your GSA/FSS or other GWAC Contract? If so, what is your contract number?_____________________ [ ] yes [ ] no Does your equipment conform to the Buy American Act and RFO 52.225-1? 52.225-1 Buy American-Supplies | Acquisition.GOV What is the estimated Delivery Date After Receipt of Order (ARO)? _____________ Please include the following information: Company Name: POC: UEI: Address: Email: In addition to providing the information requested above, responding companies are encouraged to include any relevant information (specifications, cut sheets, brochures, capability statement, experience etc.) to confirm the company s ability to meet the requirements outlined in this request. Disclaimer: This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. After reviewing the responses received, a pre-solicitation synopsis and solicitation may be published in Contract Opportunities (https://sam.gov/). Submit Capability Statements to: Department of Veterans Affairs, VISN 20 Attn: Krystal Weeks, no later than 2:00 PM (PDT), August 13, 2026. Responses must be submitted via e-mail to: krystal.weeks@va.gov and nco20supplyteam2@va.gov . Note: Do not include Proprietary, classified, confidential, or sensitive information in responses.

Go deeper on this solicitation

FedSift reads the full solicitation package — every attachment — and pre-extracts the compliance matrix, evaluation factors, key risks, win themes and deal-breakers, each with a verbatim quote and the exact PDF page it came from. It scores the opportunity against your company profile, tells you whether to bid as prime or sub, and ranks teaming partners who could close your gaps.

Open the AI analysis in FedSift →

Free forever plan — no credit card. Browse solicitations without an account; sign in for AI analysis and matching.

Other open solicitations in NAICS 334516

All NAICS 334516 solicitations →

More from VETERANS AFFAIRS, DEPARTMENT OF

All VETERANS AFFAIRS, DEPARTMENT OF solicitations →

Source: this notice on SAM.gov. FedSift republishes public federal procurement data and is not affiliated with the U.S. Government. Always confirm dates and requirements against SAM.gov before responding.