FedSift

SolicitationsVETERANS AFFAIRS, DEPARTMENT OFNAICS 334510

6515--Vestibular Diagnostic Suite

VETERANS AFFAIRS, DEPARTMENT OF · Solicitation 36C26226Q0993 · NAICS 334510 · Unrestricted (full and open) · Closed

Solicitation details

Solicitation number36C26226Q0993
Notice ID618cec828e154bbd83c3b732fd88841e
AgencyVETERANS AFFAIRS, DEPARTMENT OF
Sub-tierVETERANS AFFAIRS, DEPARTMENT OF
Contracting office262-NETWORK CONTRACT OFFICE 22 (36C262)
NAICS code334510
Product / service code (PSC)6515
Set-asideUnrestricted (full and open)
Notice typeSources Sought
Posted18 June 2026
Response deadline26 June 2026 (closed)
Place of performancePhoenix, AZ, USA

Description

THIS REQUEST FOR INFORMATION (RFI) / SOURCES SOUGHT NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION. SUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT/RFI DESCRIPTION This is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 334510 (size standard of 1,250 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published. The list of salient characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required. STATEMENT OF WORK Description: The Department of Veterans Affairs Phoenix Healthcare System is looking to purchase one Vestibular Diagnostic Suite equivalent to Interacoustics VisualEyes 525 with Orion Auto-Traverse Rotational Chair that is designed for the assessment of vestibular and balance disorders. This system must integrate various tests to provide a complete analysis of a patient s dizziness or balance issues through its own software. The software must interface with state-of-the-art hardware components to perform video-nystagmography (VNG), Video Head Impulse Test (vHIT), and rotational chair tests. These assessments must collectively offer a holistic view of a patient s peripheral and central vestibular function, which is crucial for accurate diagnosis and treatment of vestibular disorders. Place of Performance: VA Phoenix Healthcare System 650 East Indian School Road Audiology, Vestibular Clinic, Room A2107 Phoenix, AZ 85012 Deliverables: CLIN Description Qty UOM 0001 Vestibular Diagnostic Suite equivalent to Interacoustics VisualEyes 525 Chair & Controller and all required accessories to perform required functions listed under the salient characteristics 1 EA 0002 OtoAccess Database or equivalent data software access 1 EA 0003 Installation and Training 1 JB The VAAR 852.212-71 Gray Market and Counterfeit Items applies on this acquisition. No remanufacturers or gray market items will be acceptable. Vendor shall be an Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller verified by an authorization letter or other documents from the OEM signed. The letter must either state specific product(s) quoted or that the quoter is an authorized distributor for all the manufacturer s products. This letter must be on the manufacturer s letterhead and contains the signature of an authorized official for the manufacturer. Salient Characteristics: NOTE: Potential quoters must be aware that the items being acquired are procured as Brand Name or Equal. For those items that are or equal , a description of the salient characteristics is outlined below. It is quoter s responsibility to demonstrate its quote meeting the salient physical and functional characteristics included in this solicitation. If the quote does NOT demonstrate, the quote will be considered non-responsive. The interested parties bear full responsibility to ensure their submission demonstrates to the government that they can satisfy the requirement by providing the brand name or equal to the supplies being requested. Must be FDA-cleared for clinical vestibular diagnostic use in the United States. Must provide comprehensive, advanced vestibular batteries including the following: Videonystagmography (VNG) including spontaneous, saccade, smooth pursuit, optokinetic, positioning, and positional tests Video Head Impulse Test (vHIT) for horizontal, right-anterior/left-posterior, & left anterior/right-posterior semi-circular canals Air caloric Water caloric Must be capable of assessing the vestibulo-ocular reflex (VOR) under varying eye-gazing directions, head positions, and rotational movements in order to support differentiation between peripheral and central vestibular disorders. Must include integrated eye-tracking capabilities with automated pupil detection and rea-time tracking and must provide a minimum of display resolution of 1080p Full HD or higher. Must include infrared video goggles capable of recording eye movements during visual, positional, and caloric stimulation. Must be fully compatible with a computer controlled rotational chair capable of precise rotation at variable speeds and accelerations. Must calculate vestibular parameters such as gain, phase, and symmetry for bilateral vestibular assessment. Must allow rotation in multiple directions and speeds to evaluate bilateral vestibular function not measurable through unilateral tests alone. Must support standard vestibular testing protocols including Sinusoidal Harmonic Acceleration (SHA) and Velocity Step testing. Must include, at minimum, a desktop computer monitor, rotational chair with enclosure, binocular VNG goggles, and a vestibular workstation PC. Must meet the following minimum computer specifications: Desktop PC: One PCI Express card available (FireWire® systems only). USB port required (expanded by USB hub) Intel i5 processor 2.5 GHz or better, 5th generation or newer, with a minimum 4 cores (4 threads). Minimum 8 GB RAM or more. Hard drive with a minimum of 250 GB space. Must allow performance of a complete VNG test battery for following tests at minimum: Spontaneous nystagmus testing Gaze testing Saccade testing Smooth pursuit testing Optokinetic testing Positional testing Visual fixation suppression testing Bithermal caloric testing Must include automated analysis of vestibular test results including calculation of slow phase velocity, unilateral weakness, and directional preponderance. Must display real-time eye movement waveforms and video recordings during testing. Must integrate with the Rotary Chair system with Otoaccess database currently installed in Murrieta community-based outpatient clinic Must be compatible with existing OtoAccess database. Must include integrated software capable of storing patient data and generating comprehensive vestibular test reports. Must allow video recording and playback of eye movements for clinical review and documentation. Must allow printing of diagnostic reports and test summaries for inclusion in the patient medical record. Must include Vorteq assessment sensor package including the head position monitor with torsional tracker to conduct advanced benign paroxysmal position vertigo repositioning maneuvers. Videonystagmography system must have binocular cameras for viewing both eyes during testing. Video Head Impulse Test system camera must have capacity to be moved to either eye for recording of right or left eye as needed. The information identified above is intended to be descriptive, not restrictive and to indicate the quality that will be satisfactory. The interested parties bear full responsibility to ensure their submission demonstrates to the government that they can provide the brand name or equal to supplies being requested. Privacy & Confidentiality Statement: In reference to VHA Handbook 6500.6 Appendix A, Block 6, this acquisition does not involve connection of contractor-owned IT devices to a VA network. Therefore, C&A, SAP, & the following from App C does not apply. This acquisition for VA-owned IT device(s) does not involve connection to a VA network. In reference to VHA Handbook 6500.6 Appendix A, Block 7, the equipment does not involve storing, generating, transmitting, or exchanging VA sensitive information. Therefore, the following from App C does not apply. The contractor, their personnel, and their subcontractors shall be subject to the Federal laws, regulations, standards, and VA Directives and Handbooks regarding information protection, patient privacy, and information system security as delineated in this contract. During contract performance, contractors may require access to VA facility, equipment, information systems, or sensitive data; to provide services, install, train, maintain or repair equipment. VA Course No. VA10176 is privacy training required for VA contractors requiring access to VA facilities for more than 2 consecutive days or any access to VA information systems. Training will be completed prior to being granted…

Go deeper on this solicitation

FedSift reads the full solicitation package — every attachment — and pre-extracts the compliance matrix, evaluation factors, key risks, win themes and deal-breakers, each with a verbatim quote and the exact PDF page it came from. It scores the opportunity against your company profile, tells you whether to bid as prime or sub, and ranks teaming partners who could close your gaps.

Open the AI analysis in FedSift →

Free forever plan — no credit card. Browse solicitations without an account; sign in for AI analysis and matching.

Other open solicitations in NAICS 334510

All NAICS 334510 solicitations →

More from VETERANS AFFAIRS, DEPARTMENT OF

All VETERANS AFFAIRS, DEPARTMENT OF solicitations →

Source: this notice on SAM.gov. FedSift republishes public federal procurement data and is not affiliated with the U.S. Government. Always confirm dates and requirements against SAM.gov before responding.