FedSift

SolicitationsDEPT OF DEFENSENAICS 334519

Military Housing Office Inspection Kits

DEPT OF DEFENSE · Solicitation MHO194 · NAICS 334519 · Total Small Business Set-Aside (FAR 19.5) · Closed

Solicitation details

Solicitation numberMHO194
Notice ID89c9f249f9064243858735bae3d8ecfa
AgencyDEPT OF DEFENSE
Sub-tierDEPT OF THE AIR FORCE
Contracting officeFA8903 772 ESS PK
NAICS code334519
Product / service code (PSC)6625
Set-asideTotal Small Business Set-Aside (FAR 19.5)
Notice typeSolicitation
Posted30 June 2026
Response deadline06 July 2026 (closed)
Place of performanceSan Antonio, TX, USA

Description

Amended paragraph #3 & #7 on 30 June 2026 (see attachments) 1. Binoculars; Quantity = 194 Make/Model: Fujinon 10x50, Steiner 10x50 Military Marine, or equivalent Specifications for "Steinger Military Marine 10x50" (or equal) products: Magnification: 10x Objective Lens Diameter: No less than 50mm Field of View: No less than 327 ft at 1000 yds Focus: Auto Focus System Optics: Fully coated high contrast optics Close Focus: No more than 75 ft IP Distance: 56-74mm Diopter Range: +/- 5 pdt Luminosity: No less than 25 Durability: Rubber Armoring (Rugged), Waterproof, Housing designed for minimum 8G impact Includes: Objective Covers, Carrying Case, High Contrast, Neck Strap 2. Borescopes; Quantity = 194 Make/Model: Teslong TD-500, Kentfaith Dual -Lens Articulating Borescope, or equivalent Specifications for "Teslong TD-500" (or equal) products: Camera Pixels: 1.0 Megapixel minimum Probe: 2 Way Articulating Probe, 210 deg articulation, diameter no greater than 8.55 mm Field of View: 60 degrees minimum Display: 5 inch minimum, with a screen resolution of at least 854x480 pixels Probe Length: Between 4 to 8 feet Image Resolution: 1920x1080 pixel Durability: IP 67 waterproof 3. Combination IR and Probe Thermometers; Quantity = 194 Thermoworks IRT-2 with standard type T straight probe or equal. Minimum IR Range -40 to 250 deg F Minimum IR accuracy +/- 1.8 deg F from 32 deg to 149 deg F Thermocoupler (probe) specifications Minimum Range 32 deg F to 149 deg F minimum Minimum Accuracy +/- 0.9 deg F from 32 deg F to 149 deg F Must include a type T straight Penetration Probe, standard tip 4. Combustible Gas Meters / Combustible Gas Leak Detection; Quantity = 194 Make/Model: TPI 775, BPI Basics Kit, Gas Leak Detector CO Monitor, or equivalent Specifications for "TPI 775 " (or equal) products: Carbon Monoxide Detection: Resolution: 1ppm or lower Range: 0-2,000ppm or larger range Accuracy: +/- 5ppm or 5% of reading (whichever is greater) or better Combustible Gas Leak Detection: Resolution: <50ppm Range: 0 50,000 ppm Accuracy: +/- 10% Detectable Gases: Must detect Natural Gas and Propane Alarms: Audible alarm for leaks, adjustable gas upper alarm threshold limit for alarm to permit gas leak isolation 5. GFCI Testers; Quantity = 194 Make/Model: Ideal 61-502 or equivalent Specifications for "Ideal 61-502 120V AC Receptacle Tester" (or equal) product: Certification: UL 1436 and CSA C22.2 no 160 listed Detection Capabilities: Detects open ground, reverse polarity, open hot, open neutral, hot and ground reversed, and hot on neutral with hot open. Functionality: Push to Test function to test operation of GFCI receptacles. 6. Water Pressure Testers; Quantity = 194 Make/Model: Watts 3/4 Inch Plastic Water Pressure Test Guage, or equivalent Specifications for "WATTS inch Plastic Water Pressure Test Gauge" (or equal) Connection: inch FIP connection Accuracy: ASME, type B Working Pressure: 0-140 psi Max Pressure: 200 psi 7. Thermal Imagers; Quantity = 194 Thermal imager minmum specifications: Thermal resolution: 160 x 120 pixels or greater Thermal sensitivity: < 150 mK or lower Field of View: 57 deg x 44 deg or higher Temperature range: 32 deg F to 170 deg F or greater Image modes: Thermal, Visual and mode that embosses visual details into thermal images Digital camera minimum specifications 2 MP or greater 70deg x 55 deg minimum field of view 320 x 240 pixel minimal color display Built in Moisture Detection both pinless and external pin probes (in lieu of this the vender can provide a separate moisture meter) Pinless depth to 0.75 inches Pin probes provided for pin operation Range 7% to 30% or greater with accuracy to +/- 1.5% Range 30% to 100% with reference only accuracy Built in Air Temperature, Relative Humidity and Dew Point sensors (in lieu of this the vender can provide a separate meter to measure temperature, relative humidity and dew point) Temperature range: 32 deg F to 120 deg F or greater with minimum accuracy of +/- 1.1 deg F or better Relative Humidity range: 10%-90% or greater/ accuracy +/- 2.5% or better Dew Point -20 deg F to 120 Deg F or greater with accuracy of +/- 1.8 Deg F or better

Go deeper on this solicitation

FedSift reads the full solicitation package — every attachment — and pre-extracts the compliance matrix, evaluation factors, key risks, win themes and deal-breakers, each with a verbatim quote and the exact PDF page it came from. It scores the opportunity against your company profile, tells you whether to bid as prime or sub, and ranks teaming partners who could close your gaps.

Open the AI analysis in FedSift →

Free forever plan — no credit card. Browse solicitations without an account; sign in for AI analysis and matching.

Other open solicitations in NAICS 334519

All NAICS 334519 solicitations →

More from DEPT OF DEFENSE

All DEPT OF DEFENSE solicitations →

Source: this notice on SAM.gov. FedSift republishes public federal procurement data and is not affiliated with the U.S. Government. Always confirm dates and requirements against SAM.gov before responding.