6515--Transcranial Doppler

Inactive on SAM.gov — responses were due 17 Aug 2026 · Small Business Set Aside - Total · Department of Veterans Affairs (VA) · Los Angeles · NAICS 339112 · Solicitation 36C26226Q1357

Following NAICS 339112? Get new solicitations in it by email as they post — no account needed.

Email me new ones

A newer version of this notice has been posted. SAM.gov republished solicitation 36C26226Q1357 on 27 August 2026. This page is kept because it is a real record, but the current requirement, dates and attachments are on the latest version. Read the latest version →

What happened next

SAM.gov marked this notice inactive — responses were due 17 August 2026.

No award notice on SAM.gov yet. Not every award is posted there, so this does not mean it went unawarded.

Email me when the award is announced. One email, when SAM.gov posts the award notice. Not every award is posted there; if none appears within six months we'll tell you and stop. No account needed.

Solicitation details

Solicitation number36C26226Q1357
Notice IDa6552254efaa4ff4aab186164c962d56
AgencyDepartment of Veterans Affairs (VA)
Contracting office262-NETWORK CONTRACT OFFICE 22 (36C262)
NAICS code339112 — Surgical and Medical Instrument Manufacturing
Product / service code (PSC)6515
FOBDestination
ResellersCan be bid as a nonmanufacturer: 500 or fewer employees, normally sells this item, takes possession of it, and supplies a product made in the US by a small manufacturer unless SBA has waived that. 13 CFR 121.406(b)
Set-asideSmall Business Set Aside - Total
Notice typeCombined Synopsis/Solicitation
Posted13 August 2026
Response deadline17 August 2026 (closed)
Place of performanceLos Angeles

Get new NAICS 339112 solicitations by email

This one has closed. We'll email you when new NAICS 339112 (Surgical and Medical Instrument Manufacturing) solicitations post — the first email lists what is open right now, then at most once a week, only when something new posts. No account needed; unsubscribe in a click.

Description

This is a combined synopsis/solicitation for commercial items in accordance with FAR Part 13 prepared with the format in Subpart 12.6, as supplemented with additional information included in this notice. The acquisition strategy will be a Small Business set-aside to best meet the needs of the Government. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. (ii) Solicitation number 36C26226Q1357 is issued as a Request for Quotation (RFQ). (iii) The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2021-04. (iv) This is set-aside for small businesses. This will be a firm fixed price award, provisions associated with this procurement; NAICS code 339112 and small business size standard is 1,000 employees. (v) The technical specifications are listed as brand name or equal (FAR 52.211-6 is applicable). For equal items, please include technical specifications of the ultrasound systems and components. If technical specifications showing how the equal product meets the salient characteristics are not included, your quote will be considered non-responsive. ****Please refer to Salient Characteristics for full details.**** NOTE: Potential offers must be aware that the items being acquired are procured as Brand Name or Equal. For those items that are or equal , a description of the salient characteristics outlined above. The FAR Clause 52.211-6 Brand Name or Equal applies to this acquisition. Any items quoted as equal not confirming to the requirements of clause 52.211-6 will be considered non- responsive and not considered for award. Vendor Requirements: 1. Vendor shall provide delivery. 2. Vendor shall provide original equipment manufacturer (OEM) comprehensive warranty on the product(s) starting from the first day of delivery. 3. Vendor provides guarantee equipment is free of defects. 4. Authorized distributor letter 5. FOB Destination delivery shall occur within 90 business days after award to the following destination address: Department of Veterans Affairs VA Los Angeles Healthcare System 11301 Wilshire Blvd. Los Angeles CA 90073. (xii) Quotes are to be received no later than 3:00PM PST, August 17, 2026 at email address: Hanan.McCullick@va.gov, subject Quote: # 36C26226Q1357 [VENDOR NAME] late quotes shall not be accepted. Telephone responses shall not be accepted. Any questions regarding this solicitation shall be submitted no later than 10:00 AM PST August 14, 2026. Schedule of Supplies: Salient Characteristics Transcranial Doppler Core System Requirements: Digital system with M-Mode display. At least 2 independent channels capable of operating between 1 16/20 MHz. 2 probes that can operate simultaneously. Electronically switchable between pulsed-wave (PW) and continuous-wave (CW) modes for 4 MHz and 8MHz probes. Spectra and audio recording capability. Remote control of all vital functions. User-configurable test protocols for different clinical scenarios. Software Features: 2-channel micro-emboli detection program. Color spectrum M-Mode display. Online display of parameters (depth, mean velocity, SV, PI, RI, power, etc.). Database with data sorting and ability to insert new patient data. Report generation facility. Bi-lateral monitoring software with lightweight headband probe fixation. 4/8-view spectra display during monitoring. Probes and Accessories: 2 MHz TCD probes (2 units). 2 MHz hand-held diagnostic probe (1 unit). Lightweight headband for two probes. Stereo headphones (1 unit). Conductive gel (24 tubes, 200 250 ml each). Installation Considerations: Computer and Connectivity Medical-grade PC with: Pentium IV or higher processor. 512 MB RAM or more. 80 GB or larger HDD. 17 or higher, high-resolution LCD TFT active matrix color display. Windows XP or higher OS. Network compatibility. Network support: DICOM, DICOM Structured Reporting, HL7, GDT, SQL. Unlimited review stations for interpretation and post editing. Power and Portability: Supply on a sturdy trolley. Integrated color laser printer. UPS (uninterruptible power supply). Optional: built-in rechargeable battery for portability. Environmental Operation: Storable in ambient temperature 0-50 degrees Celsius and relative humidity 15-90%. Operable in 20-30 degrees Celsius with humidity <70% Meets IEC-60601-1-2:2001 (or equivalent) safety standards. Summary: A minimum TCD system should be a digital, multi-channel, multi-probe capable unit with robust software for emboli detection, spectral and audio recording, and network integration, supported by a compatible PC, essential probes, accessories, and environmental resilience. These specs ensure the system can be used effectively in neurology, ICU, and neurosurgery settings. Contractor must comply with all VA mandated and local permitted/safety requirements. Contractor will dispose of all boxes, trash and debris resulting from installation IAW hospital policy. Remote Support - The contractor will ensure they understand and implement the IT security requirements for system interconnection documents required per the Memorandum of Understanding or Interconnection Agreement (MOU-ISA). The standard operating procedure (SOP) and a template for a MOU-ISA are located on the Information Protection Risk Management (IPRM) Portal and can be provided to the contractor. The facility will work with the contractor to establish a MOU-ISA for this requirement/equipment. Delivery of equipment will be NLT 120 days ARO. Installation of equipment and/or clinical training will be NLT five months after equipment delivery, if applicable. Support Features: Telephone Support: Must include 24x7x365 Unlimited Telephone Support, 24x7 Go-Live Clinical Support by Telephone per Department, 24x7 Ongoing Clinical Support by Telephone per Department for the life of the system. This support must be at no additional cost to the Government. Facility will sponsor and submit necessary paperwork through appropriate channels in order for equipment contained in this contract to obtain TRM and/or RMF and/or any other necessary cybersecurity approvals. Facility will sponsor and submit necessary paperwork through appropriate channels in order for equipment contained in this contract to obtain AVHE certification/approval. Warranty: Transcranial Doppler System - Two years on system. One year on remote, headset and other accessories. 90 days on probes. Supply items are warranted for 90 days from the date of shipment. The products are warranted to be free from material defects in workmanship or material under normal use and service for the warranty period. Third party items carry OEM warranty.

Version history

SAM.gov has posted 2 notices under solicitation 36C26226Q1357, oldest first.

Documents in the solicitation package

1 file is attached to this notice.

  • 36C26226Q1357.docx

Download all 1 file as one ZIPFree account, no credit card.

Reading them for requirements? FedSift turns the package into a compliance matrix — every requirement with the page it came from, exportable to Excel.

Or download them one at a time from SAM.gov.

Go deeper on this solicitation

FedSift reads the full solicitation package — every attachment — and pre-extracts the compliance matrix, evaluation factors, key risks, win themes and deal-breakers, each with a verbatim quote and the exact PDF page it came from. It scores the opportunity against your company profile, tells you whether to bid as prime or sub, and ranks teaming partners who could close your gaps.

Open the AI analysis in FedSift →

Free forever plan — no credit card. Browse solicitations without an account; sign in for AI analysis and matching.

Market context: VA and NAICS 339112

About the buyer and the industry, not this specific solicitation. Source: USASpending.gov award data, updated nightly.

  • In fiscal year 2026, VA obligated $870.2M across 3,711 contract actions under NAICS 339112.
  • 738 contracts worth $525.6M in this category end within the next 18 months.

VA contracts under NAICS 339112 →

Other open solicitations in NAICS 339112

All NAICS 339112 solicitations →

More from Department of Veterans Affairs

All VA solicitations →

Source: this notice on SAM.gov. FedSift republishes public federal procurement data and is not affiliated with the U.S. Government. Always confirm dates and requirements against SAM.gov before responding.

FedSift turns SAM.gov and USASpending data into federal BD intelligence — smart matches, recompete radar, cited AI solicitation analysis and compliance matrices.

Source data: SAM.gov (solicitations) and USASpending.gov (awards), refreshed nightly. FedSift is not affiliated with the U.S. Government.

Pricing · Privacy · Terms · support@fedsift.app