Ceiling Lift Systems Installation and Removal of Existing Systems
Inactive on SAM.gov — responses were due 22 Sep 2026 · No Set aside used · Department of Veterans Affairs (VA) · White River Junction, VT · Qty 21 · NAICS 339113 · Solicitation 36C24126Q0819
Following NAICS 339113? Get new solicitations in it by email as they post — no account needed.
A newer version of this notice has been posted. SAM.gov republished solicitation 36C24126Q0819 on 25 September 2026. This page is kept because it is a real record, but the current requirement, dates and attachments are on the latest version. Read the latest version →
What happened next
SAM.gov marked this notice inactive — responses were due 22 September 2026.
Awarded to GULDMANN, INC. TAMPA 33626 FLK for $245K, posted 25 September 2026. Read the award notice →
This one has closed. We'll email you when new NAICS 339113 (Surgical Appliance and Supplies Manufacturing) solicitations post — the first email lists what is open right now, then at most once a week, only when something new posts. No account needed; unsubscribe in a click.
Description
Description This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01. This solicitation is unrestricted. The associated North American Industrial Classification System (NAICS) code for this procurement is 339113 - Surgical Appliance and Supplies Manufacturing, with a small business size standard of 800 Employees. The FSC/PSC is 6530 - Hospital Furniture, Equipment, Utensils, and Supplies. The Network Contracting Office 1 is seeking to purchase QTY 21 patient ceiling lift systems along with installation of the 21 lifts. Removal of existing QTY 18 patient ceiling lift systems. This is for Guldmann brand name or Equal. All interested companies shall provide quotations for the following: Supplies/Services Description Qty Unit of Measure Unit Price Total Price GH3+250 ( 550lbs) Hoist, Wi?, Scale, 1 CLM and Service, Medium hanger bar, 5m X 10m xy system, manual position locks for hoist and tracks, all hardware included GH3+375 (825lb)Wi?, Scale, CLM and 1 Service, medium hanger bar, 3m linear track GH3+250 ( 550lbs) Hoist, Wi?, Scale, 8 CLM and Service, Medium hanger bar, 4m X 4m xy system, all hardware included GH3+375 (825lb)Wi?, Scale, CLM and 1 Service, medium hanger bar, 4m X 4m xy system GH3+250 (550lbs) Wi?, Scale, Clm and 2 Service, medium hanger bar,3m linear track, continuous charge, all hardware GH3+ 250 (550lb) Wi?, Scale, Clm and 3 service, medium hanger bar, 4m linear PERFORMANCE WORK STATEMENT (PWS) Patient Ceiling Lift Systems White River Junction VA Healthcare System 1. INTRODUCTION This requirement is for the removal and disposal of 18 end-of-life ceiling lift systems and the furnishing, installation, testing, and commissioning of 21 new patient ceiling lift systems throughout the White River Junction VA Healthcare System campus. 2. BACKGROUND White River Junction VAMC has 18 end-of-life Handimove lift systems located in the Granite, Birches, and Mountains buildings and requires patient lifts in three additional ICU rooms. The purpose of this project is to replace the existing systems and add three ceiling lift systems in the ICU. 3. SCOPE OF WORK Furnish and install 21 complete patient ceiling lift and rail systems. Remove and dispose of 18 existing ceiling lift systems and associated equipment designated for removal. 4. PERIOD OF PERFORMANCE To be determined by the Contracting Officer. Installation shall be coordinated with room availability and clinical operations. 5. HOURS OF OPERATION Work shall normally be performed between 7:00 a.m. and 4:30 p.m., Monday through Friday, excluding Federal holidays, unless otherwise coordinated and approved by the VA. 6. GENERAL REQUIREMENTS All installations shall comply with applicable requirements of VHA Patient Safety Alert AL14-07, including completion of the VHA Installation or Relocation Checklist for Ceiling Mounted Patient Lifts for each installed system, in addition to manufacturer-required checklists. Coordinate with VA Engineering to maintain access to mechanical, HVAC, fire protection, electrical, and other building systems within the installation area. Coordinate installation schedules with the Local POC and affected clinical services. Provide qualified personnel, materials, equipment, tools, and services necessary for a safe and fully operational installation. Provide evidence of required weight/load testing for each installed system and coordinate testing for VA oversight. Mitigate hazards created by installation and comply with applicable construction safety, infection-control, electrical-safety, firestopping, and above-ceiling permit requirements. Contractor personnel must: Wear visible identification at all times. Park only in designated areas (no reimbursement for violations). Follow VA restrictions on smoking, cellphone/two?way radio use near medical equipment, weapon possession, and item inspection. 7. STRUCTURAL AND SEISMIC REQUIREMENTS Designs must follow: VA Directive 7512, Seismic Safety of VA Buildings (AUG 2017) VA Handbook H-18-8, Seismic Design Requirements (NOV 2024) VA Specs Section 13 05 41, Seismic Restraint Requirements for Non Structural Components (JAN 2021) Required structural drawings and calculations shall be signed and sealed by a Professional Engineer (PE) appropriately licensed for the project location. Where required by applicable codes or VA requirements, provide Special Seismic Certification and supporting documentation for the applicable equipment/components. Contractor must revise drawings if directed by the Medical Center. 8. TRAINING Contractor must provide training including: Technical training Operational training Administrative training Hardware and software troubleshooting SALIENT CHARACTERISTICS Patient Ceiling Lift Systems QTY 21 The contractor shall provide complete patient ceiling lift systems, including ceiling-mounted hoists, track/rail systems, hanger bars, controls, charging equipment, slings, mounting hardware, and associated components necessary to provide fully functional systems. All applicable ceiling-mounted hoists, rails, and components shall comply with ISO 10535:2021. XY (H-Track/Traverse) Full-Room Coverage Rail System Provide XY/traverse ceiling track systems capable of providing multidirectional patient-transfer coverage throughout the designated areas. Required configurations: 5 m 10 m coverage area with trainer capability QTY 1 4 m 4 m coverage area QTY 9 4 m 3 m coverage area QTY 2 3 m 3 m coverage area QTY 1 The systems shall: Multidirectional movement throughout the required coverage area. Accommodate the applicable room layout and structural conditions. Be capable of being wall mounted or beam mounted. 10 Wall mounted 12 Beam mounted Provide sufficient structural capacity for the proposed patient lift and its rated load. Linear Track Systems Provide linear ceiling track systems in the following nominal lengths: 3 m linear track QTY 3 4 m linear track QTY 4 6 m linear track QTY 1 Track systems shall: Be constructed of durable, corrosion-resistant material suitable for repeated use in a healthcare environment. Have a durable surface finish suitable for routine healthcare cleaning and disinfection. Provide sufficient structural capacity for the associated ceiling lift and its required safe working load. Required minimum capacities: 3 m track: 550 lbs. 4 m track: 825 lbs. 6 m track: 550 lbs. Patient Ceiling Lift Minimum 550-lb Capacity QTY 17 Provide powered ceiling-mounted patient lifts with a minimum rated lifting capacity of 550 lbs. Each lift shall: Be available with powered horizontal travel along the ceiling track, controllable through the lift's caregiver control system. Provide connectivity capable of supporting required usage monitoring, service alerts, and equipment data logging through a centralized digital platform. Include mechanical and electrical emergency-lowering capability, emergency stop, and overload protection. Provide position-locking capability where required for safe operation. Utilize a rechargeable battery system capable of supporting normal clinical operations. Provide automatic activation and smooth start/stop functionality. Provide charging capability designed to maximize equipment availability and minimize caregiver intervention. Have a housing suitable for healthcare use that is impact-resistant and flame-retardant. Provide continuous or automatic charging through the installed rail/charging system. Include an integrated patient-weighing capability. Include a caregiver hand control capable of operating required lift functions and displaying the patient's measured weight directly on the hand control. Allow the caregiver to view the patient-weight reading from the normal operating position without requiring access to or viewing of the ceiling-mounted hoist. Provide applicable lift-usage/status information to the caregiver. Hand Control - QTY 21 Display the patient weight measured by the system's integrated weighing scale directly on the hand control. Patient Ceiling Lift Minimum 825-lb Capacity QTY 4 Provide powered ceiling-mounted patient lifts with a minimum rated lifting capacity of 825 lbs. Each lift shall provide the same required safety, control, weighing, connectivity, charging, housing, and caregiver-interface capabilities specified for the 550-lb ceiling lifts, appropriately designed and rated for the higher lifting capacity. The battery…
Version history
SAM.gov has posted 2 notices under solicitation 36C24126Q0819, oldest first.
15 September 2026 — Combined Synopsis/Solicitation (this page)
FedSift reads the full solicitation package — every attachment — and pre-extracts the compliance matrix, evaluation factors, key risks, win themes and deal-breakers, each with a verbatim quote and the exact PDF page it came from. It scores the opportunity against your company profile, tells you whether to bid as prime or sub, and ranks teaming partners who could close your gaps.
Source: this notice on SAM.gov. FedSift republishes public federal procurement data and is not affiliated with the U.S. Government. Always confirm dates and requirements against SAM.gov before responding.