Inactive on SAM.gov — responses were due 20 Aug 2026 · Unrestricted (full and open) · Department of Veterans Affairs (VA) · Dallas, TX · NAICS 334510 · Solicitation 36C25726Q0689
Following NAICS 334510? Get new solicitations in it by email as they post — no account needed.
A newer version of this notice has been posted. SAM.gov republished solicitation 36C25726Q0689 on 24 August 2026. This page is kept because it is a real record, but the current requirement, dates and attachments are on the latest version. Read the latest version →
What happened next
SAM.gov marked this notice inactive — responses were due 20 August 2026.
No award notice on SAM.gov yet. Not every award is posted there, so this does not mean it went unawarded.
Email me when the award is announced. One email, when SAM.gov posts the award notice. Not every award is posted there; if none appears within six months we'll tell you and stop. No account needed.
This one has closed. We'll email you when new NAICS 334510 (Electromedical and Electrotherapeutic Apparatus Manufacturing) solicitations post — the first email lists what is open right now, then at most once a week, only when something new posts. No account needed; unsubscribe in a click.
Description
Extension of Sources Sought This market research notice is being conducted by Network Contracting Office (NCO) 17- VA South Texas (VASTHCS) facilities. The VA North Texas Health Care System (VANTHCS) has a requirement to purchase two E14CL4B Biplane Endocavity Transducers with an authorized vendor to supply and deliver the item(s) identified in Table 1 below. Currently Urology Surgical Service has no working Biplane transducers. Due to the critical diagnoses for cancer and the increase of population to provide care for, additional transducers and probes are mandatory. SCOPE OF WORK Item Item Description Quantity 9048 E14CL4B Biplane Endocavity Transducer 2 UA2507 Reprocessing SS Tray For E14CL4B, E10C4 2- Brand name or Equal Salient Characteristics E14CL4B Biplane Endocavity Transducer (Brand Name or Equal) 1. Clinical Applications Must support Transrectal, Transvaginal, and Urology applications. 2. Frequency & Acoustic Performance Frequency range must be 14 4 MHz. Focal range must be 3 60 mm. 3. Imaging Modes Required The transducer must provide all of the following modes: B?Mode M?Mode PWD (Pulsed Wave Doppler) CFM (Color Flow Mapping), including Color Doppler & Power Doppler THI (Tissue Harmonic Imaging) CEUS (Contrast?Enhanced Ultrasound) Strain Elastography Combination imaging modes 4. Biplane Imaging Requirements Must include two arrays (curved array for transverse imaging and linear array for sagittal imaging). Must support simultaneous biplane imaging, enabling visualization of two planes at once for needle guidance during biopsy/puncture procedures. 5. Image Field / Sector Requirements Transverse sector: 138 Expanded sector: 178 Sagittal field: trapezoidal, 65 mm wide, plus 2 15 expansion 6. Physical / Ergonomic Features Must include variable stiffness shaft to improve patient comfort and instrument maneuverability. Weight must be approx. 250 g. Must include Smart Button functionality to activate, freeze, store, and print images with a single press. 7. Sterilization & Reprocessing Requirements Must be fully immersible for sterilization. Must be compatible with UA2507 stainless steel reprocessing tray (or equal). 8. Compatible Ultrasound Systems Equivalent products must be compatible with the following or provide equal system interoperability: bkActiv, bkSpecto, bk3000, bk5000, bkActiv S Series Responses shall include: Business Name Business Address Point of Contact Name Phone Number E-mail Address SAM UID Number Currently registered in SAM (Yes or No). If Yes, provide expiration date. NAICS code Business Size: Small or Large Type of Business: Service-Disabled Veteran Owned (SDVOSB), Veteran Owned (VOSB), 8(a), HUBZone, Woman-Owned (WOSB), etc. GSA or VA FSS Contract Number, if applicable Place of Manufacture All businesses eligible to provide these supplies are encouraged to reply as this information may be used to determine potential set-asides for the above-noted requirement. Send responses to both the Contract Specialist. Contract Specialist: Mr. Rafael Rodriguez at Rafael.Rodriguez2@va.gov Responses in the email subject line shall state: 36C25726Q0689, Sources Sought Notice Responses due date: 08/20/2026- 11:00 AM CT DISCLAIMER: This notice is issued solely for informational and planning purposes and does not constitute a solicitation. Responses to this notice are not offers and cannot be accepted by the Department of Veterans Affairs to form a binding contract. Respondents are solely responsible for all expenses associated with responding to this notice.
Version history
SAM.gov has posted 4 notices under solicitation 36C25726Q0689, oldest first.
FedSift reads the full solicitation package — every attachment — and pre-extracts the compliance matrix, evaluation factors, key risks, win themes and deal-breakers, each with a verbatim quote and the exact PDF page it came from. It scores the opportunity against your company profile, tells you whether to bid as prime or sub, and ranks teaming partners who could close your gaps.
Source: this notice on SAM.gov. FedSift republishes public federal procurement data and is not affiliated with the U.S. Government. Always confirm dates and requirements against SAM.gov before responding.