Solicitations
› VETERANS AFFAIRS, DEPARTMENT OF
› NAICS 339113
6515--Lead Shield Containers
VETERANS AFFAIRS, DEPARTMENT OF · Solicitation 36C24626Q0804 · NAICS 339113 · Unrestricted (full and open) · Closed
This solicitation has closed.
Responses were due 30 July 2026.
The record stays published because closed procurements are what a recompete is
built from — the follow-on is typically solicited 6–18 months before the
incumbent contract ends. Open solicitations like this one are linked below.
Solicitation details
| Solicitation number | 36C24626Q0804 |
|---|
| Notice ID | bd30e58817a5449892494f98eb11c6a3 |
|---|
| Agency | VETERANS AFFAIRS, DEPARTMENT OF |
|---|
| Sub-tier | VETERANS AFFAIRS, DEPARTMENT OF |
|---|
| Contracting office | 246-NETWORK CONTRACTING OFFICE 6 (36C246) |
|---|
| NAICS code | 339113 |
|---|
| Product / service code (PSC) | 6515 |
|---|
| Set-aside | Unrestricted (full and open) |
|---|
| Notice type | Solicitation |
|---|
| Posted | 28 July 2026 |
|---|
| Response deadline | 30 July 2026 (closed) |
|---|
Description
?.## PERFORMANCE WORK STATEMENT (PWS) GENERAL: Building 42, 508 Fulton Street, Durham, NC 27705, has a requirement for radiation shielding equipment. The radiation shielding equipment is necessary for clinicians to provide patients care. BACKGROUND: Building 42 has a requirement for radiation shielding equipment. PURPOSE: The radiation shielding equipment is required for the protection of employees from high-energy radionuclides during the receiving and preparation of unit doses for patients. and is critical for the safe handling of radioactive materials. This equipment is essential for maintaining safety protocols and compliance with radiation protection standards and is crucial for patient care at Building 42, Radiation Oncology. SCOPE: Building 42 is requesting contractors to provide brand name or equal equipment that meets or exceeds the physical, functional, and performance of the listed salient characteristics in this section. The equipment feature is essential to the technical requirements to meet the needs of the Hot Lab. PHYSICAL CHARACTERISTICS: Equipment must have the physical characteristics to enable the government to perform the capabilities: PET Unit Dose Cabinet (244-205) Minimum 0.25-inch lead equivalency Lockable and shielded storage Radiation warning labeling Smooth, non-porous, cleanable surfaces Dose storage compartments Recessed dose calibrator shield Sliding shelves Shielded on all six sides for radiation protection Key-locked doors for secure storage Stainless steel countertop includes 4" (10.2 cm) backsplash and 0.5" (1.3 cm) spillproof lip Dimensions: 36.5" w x 24" depth x 36.5" h Lead Shielding: 0.25" (0.64 cm) Finish: Powder coat Doors: Key-locked Countertop: Stainless steel with 4" (10.2 cm) backsplash and 0.5" (1.3 cm) lip Countertop Height: 36.5" (92.7 cm) Weight Capacity: 1,550 lb (703 kg) Weight: 1,240 lb (562 kg) Quantity: 1 PET Shielded Sharps Container System (5730-2271) Outer container with 1-inch lead shielding Removable inner sharps container Biohazard and radiation labeling Stable, tip-resistant design Hinged cover Sliding top with lock Dimensions: 13.5625" h x 10.625" od x 6.125 id (34.4 x 27 x 15.6 cm) Weight: 160 lbs. (72.6 kg) Lead Lining: 1" (2.5 cm) Quantity: 1 Sharps Inserts (0660-0042) Compatible with PET Sharps Container Shield (5730-2271) Quantity: 1 pkg (total 12) L-Block Shield, Compact, 1.5 lead with built-in Dose Calibrator Shield (042-433) 1.5 thick lead shielding in front, 1 in base 8 x 8 x 4 adjustable lead glass window 0.86" thick lead shield surrounds calibration chamber for a total of 1" of lead shielding Quantity: 1 Interlocking Lead Brick Cave (042-434) Three-sided configuration 2-inch thick lead bricks Modular/interlocking system Flat working surface Dimensions: I.D.: 14 w x 20.5 depth x 16 h (35 x 52.1 x 40.6 cm) Lead Shielding: 2 thick (5 cm) Finish: Paint Weight: 597 lb (271 kg) Quantity: 1 Cabinet, Decay & Storage (244-162) 1-inch lead shielding Lockable cabinet Waste segregation capability Radiation labeling Supports storage and decay workflows in one unit Removable drawers Two adjustable decay shelves for storage Key-locked doors and drawers for controlled access Stainless steel countertop which includes a 4" (10.2 cm) backsplash and a 0.5" (1.3 cm) spill-proof lip Quantity: 2 Cabinet, Preparation Enclosure Base (244-192) 1-inch lead shielding Stainless steel or non-porous construction Spill-resistant Compatible with radiopharmacy enclosures Full-height double doors with locking hardware Adjustable internal shelf Dimensions: 36.5" w x 24" depth x 36.0" h (92.7 x 61 x 91.4 cm) Lead Shielding: 0.25 thick on all six sides Shelf Dimensions: 30" w x 18" depth (76.2 x 45.72 cm), 100 lb (45.4 kg) capacity, adjustable height Doors: Key-locked Countertop: Stainless steel with 4" (10.2 cm) backsplash and 0.5" (1.3 cm) spillproof lip Countertop Height: 36.5" (92.7 cm) Finish: Powder coat Weight: : 2433 lb (1104 kg) Quantity: 1 Cabinet, Sink and Waste (244-222) Dimensions: 36.5" w x 24" depth x 36.0" h (92.7 x 61 x 91.4 cm) Lead Shielding: 1" (2.54 cm) Door and Drawers: Key-locked Countertop: Stainless steel with 4" (10.2 cm) backsplash and 0.5" (1.3 cm) spillproof lip Countertop Height: 36.5" (92.7 cm) Faucet: Hands-free operation Electronic faucet with mixer to adjust temperature Below deck battery pack requires six 1.5V batteries (included) Finish: Powder coat Weight: 942 lb (429 kg) Quantity: 1 FUNCTIONAL AND PERFORMANCE CHARACTERISTICS: Equipment must provide the functional and performance capability as listed in section above. SOFTWARE: N/A INSTALLATION AND TRAINING: The Contractor shall provide all management, tools, parts, materials (including quality control materials, and consumable items), equipment, travel, and labor necessary to provide and install all equipment described above. Contractor shall provide instructions and training to the end user. WARRANTY OF EQUIPMENT: Government requirement for standard manufacturer industry warranty term. Government does not accept extended warranty, which requires advance payment. DELIVERY SCHEDULE: All items to be delivered after receipt of purchase order not earlier than 08/01/26 but not later than 09/30/2026. PLACE OF DELIVERY: Durham VA Building 52, 508 Fulton Street, Durham, NC 27705 between the hours 0800-1600. Delivery during any holiday will not be accepted.
Go deeper on this solicitation
FedSift reads the full solicitation package — every attachment — and pre-extracts
the compliance matrix, evaluation factors, key risks, win themes and
deal-breakers, each with a verbatim quote and the exact PDF page it came from. It
scores the opportunity against your company profile, tells you whether to bid as
prime or sub, and ranks teaming partners who could close your gaps.
Open the AI analysis in FedSift →
Free forever plan — no credit card.
Browse solicitations without an account; sign in for AI analysis and matching.
Other open solicitations in NAICS 339113
All NAICS 339113 solicitations →
More from VETERANS AFFAIRS, DEPARTMENT OF
- 6640--Albany VAMC PLMS MALDI NEW CONTRACT FY 27 (VA-27-00006444)VETERANS AFFAIRS, DEPARTMENT OF · Due 13 September 2026
- Fort Sam Houston National Cemetery Tree Pruning Cascading EvaluationVETERANS AFFAIRS, DEPARTMENT OF · Due 13 September 2026
- Cardio-Pulmonary BoomsVETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- 6835-- BULK OXYGEN (Base+4 Option)VETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- Specimen Barcode Software Iowa City VAVETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- Dental Imaging Equipment- CS 9600, Radiographic Units, and sensor kitsVETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- Dental Imaging Equipment- CS 9600, Radiographic Units, and sensor kitsVETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- NEUROFORTIS NEUROSMART DRIVE HEADSTAGE KITVETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
All VETERANS AFFAIRS, DEPARTMENT OF solicitations →
Source: this notice on SAM.gov.
FedSift republishes public federal procurement data and is not affiliated with
the U.S. Government. Always confirm dates and requirements against SAM.gov
before responding.