4610--Engineering Request - SPS REVERSE OSMOSIS | 538-26-3-6064-0049 (VA-26-00079545) - VAMC Chillicothe

Closed — responses were due 22 Sep 2026 · Small Business Set Aside - Total · Department of Veterans Affairs (VA) · Chillicothe, OH · NAICS 221310 · Solicitation 36C25026Q1034

Following NAICS 221310? Get new solicitations in it by email as they post — no account needed.

Email me new ones

Solicitation details

Solicitation number36C25026Q1034
Notice IDc3b3cdffd5a5455285dda9229cf65ed1
AgencyDepartment of Veterans Affairs (VA)
Contracting office250-NETWORK CONTRACT OFFICE 10 (36C250)
NAICS code221310 — Water Supply and Irrigation Systems
Product / service code (PSC)4610
Set-asideSmall Business Set Aside - Total
Notice typeCombined Synopsis/Solicitation
Posted21 September 2026
Response deadline22 September 2026 (closed)
Place of performanceChillicothe, OH, USA

Description

The purpose of this amendment is to post questions received and provide the facilities responses. The response date and time remain unchanged. Are the 0.2 Micron Filter Cartridges the ones that are for the tank vent filter we would be providing? Or is this for an existing endotoxin filter housing the facility has? 0.2 Micron Filter Cartridges are for bacterial removal from water and to be compatible with housing provided under CLIN 0003. Tank vent cartridges are maintained separately and not within scope. What flow rates do the 60-gallon and 160-gallon storage tank loop return need to handle? Specifically, when sizing the loop return flow meter we need to ensure it can handle the pump demand. I would assume 20 GPM and 40 GPM based on the UV assembly? Return is being constrained via 3gpm flow control device. Pumps are pressure sensing variable flow rate. Both flow control and pumps are not within scope of the solicitation. UV sized for peak demand. Are there existing pumps within the facility that they are keeping? I do not see a distribution pump mentioned in this bid. Pumps are not within scope. Do you have a list of existing equipment that is being kept for both systems? No What are the distribution loop sizes, loop material and loop length are they existing or is this a new loop? Modifying existing loop. Mixed materials, CPVC and Polypropylene. Loop is approximately 240 LF with mixed sizes of 1 and 1-1/2

Version history

SAM.gov has posted 2 notices under solicitation 36C25026Q1034, oldest first.

Go deeper on this solicitation

FedSift reads the full solicitation package — every attachment — and pre-extracts the compliance matrix, evaluation factors, key risks, win themes and deal-breakers, each with a verbatim quote and the exact PDF page it came from. It scores the opportunity against your company profile, tells you whether to bid as prime or sub, and ranks teaming partners who could close your gaps.

Open the AI analysis in FedSift →

Free forever plan — no credit card. Browse solicitations without an account; sign in for AI analysis and matching.

Market context: VA and NAICS 221310

About the buyer and the industry, not this specific solicitation. Source: USASpending.gov award data, updated nightly.

VA contracts under NAICS 221310 →

Other open solicitations in NAICS 221310

All NAICS 221310 solicitations →

More from Department of Veterans Affairs

All VA solicitations →

Source: this notice on SAM.gov. FedSift republishes public federal procurement data and is not affiliated with the U.S. Government. Always confirm dates and requirements against SAM.gov before responding.