FedSift

SolicitationsENERGY, DEPARTMENT OFNAICS 333415

Non-Refrigerated Water Re-circulating System

ENERGY, DEPARTMENT OF · Solicitation 385226 · NAICS 333415 · No Set aside used · Closed

Solicitation details

Solicitation number385226
Notice IDc6a31dc57be4467fa8ab43499b284cdc
AgencyENERGY, DEPARTMENT OF
Sub-tierENERGY, DEPARTMENT OF
Contracting officeFERMILAB - DOE CONTRACTOR
NAICS code333415
Product / service code (PSC)4130
Set-asideNo Set aside used
Notice typeSolicitation
Posted28 July 2026
Response deadline12 August 2026 (closed)
Place of performanceBatavia, IL, USA

Description

Request for Quote | brand name or item specifications equal to Fermi Forward Discovery Group (FFDG) FOR FERMILAB has a requirement for a Haskris Non-Refrigerated Water RE-Circulating System Model WW3 NAICS Code for this procurement is 333415 Fermi Forward Discovery Group (FFDG) Strategic Commercial Purchasing located in Batavia, Illinois issuing a Request for Quote (RFQ) for a commercial, single award contract to be shipped to Batavia, Illinois Warehouse 2. This is a /solicitation for commercial products or commercial services prepared in accordance with the format in FAR subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation will not be issued. Fermi Forward Discovery Group (FFDG) intends to award Firm Fixed Price (FFP) contract. This is an all-or-non requirement, and the government will award a single purchase order to the offeror responsible whose offer conforms to the requirements as stated in the solicitation and is most advantageous to the Government based on the criteria listed within this solicitation. Haskris Non-Refrigerated Water Re-Circulating Systen Model WW3 QTY 1 Electrical 115V-10-60Hz Dimensions: 40 (W) x 26 (D) x 47 (H) Features ? PLC temperature controller with alarm descriptions and logging ? Built-in, electronic facility water valve for temperature control ? High supply water temperature system cut out ? Regenerative turbine pump with robust seal and bypass relief valve ? Integrated fluid tank (non-pressurized) with fluid level switch ? Factory tested under full load Heat Exchanger Design Parameters Primary (Facility) Water Loop ? Max Water Inlet Temp: +45 F ? Min Available Water Flow: 8.8 GPM ? Max Water Inlet Pressure: 100 psi ? Optimal Differential Pressure: 15-50 psi Secondary (Application) Water Loop ? Application Heat Load: 10.6 kW ? Supply Water Temp: +68 F ? Supply Water Flow: 8.8 GPM ? Supply Water Pressure: 60 psi (max) 2. NRTL Label Oral communications are not acceptable in response to this notice. Interested organizations may submit their capabilities and qualifications to perform the effort in writing to the identified point of contact no later than 4:00 p.m. Central Standard Time on 12 AUG 2026. Such capabilities /qualifications will be evaluated solely for the purpose of determining whether to conduct this procurement on a competitive basis. A decision by the Government not to compete this proposed effort on full and open competition basis, based upon responses to this notice, is solely with the discretion of the government. The following terms and conditions shall become a part of any subsequent purchase order/subcontract resulting from this RFP. FRA General Terms and Conditions for Commercial Products and Commercial Services (8/2025) The above referenced terms and conditions are available on the Fermilab Business Services Web Site. They are PDF Format and can be accessed at the following URL: https://procurement.fnal.gov/terms-conditions/ NOTE TO OFFERORS: Please be advised that any exceptions to the specifications or to FFDG s terms and conditions may cause your proposal to be disqualified with no further consideration for an award. Any exceptions or additional terms noted on a Quote Form will not be considered and are hereby expressly rejected. Likewise, any references whether through language or hyperlink to additional terms and conditions are not accepted and are similarly rejected. FERMI Strategic Commercial Purchasing will be the procuring center for this effort. All equipment and or services are to be delivered F.O.B. Fermi National Accelerator Laboratory (Fermilab), Batavia, IL 60510, Freight prepaid (delivered). The following Representations must be completed and returned with your proposal. SARC Subcontractor Annual Reps & Certs PUR-466 Proposal Certifications The RFP response shall include a completed RFP page include a price, with a completed SARC and PUR-466. All contractual questions shall be directed to: Cathleen E. Stadler Procurement Specialist 630-840-2763 cstadler@fnal.gov

Go deeper on this solicitation

FedSift reads the full solicitation package — every attachment — and pre-extracts the compliance matrix, evaluation factors, key risks, win themes and deal-breakers, each with a verbatim quote and the exact PDF page it came from. It scores the opportunity against your company profile, tells you whether to bid as prime or sub, and ranks teaming partners who could close your gaps.

Open the AI analysis in FedSift →

Free forever plan — no credit card. Browse solicitations without an account; sign in for AI analysis and matching.

Other open solicitations in NAICS 333415

All NAICS 333415 solicitations →

More from ENERGY, DEPARTMENT OF

All ENERGY, DEPARTMENT OF solicitations →

Source: this notice on SAM.gov. FedSift republishes public federal procurement data and is not affiliated with the U.S. Government. Always confirm dates and requirements against SAM.gov before responding.