FedSift

SolicitationsDEPT OF DEFENSENAICS 332420

Oil/ Coolant Storage & Dispenser System

DEPT OF DEFENSE · Solicitation FA452826QSP02 · NAICS 332420 · Total Small Business Set-Aside (FAR 19.5) · Closed

Solicitation details

Solicitation numberFA452826QSP02
Notice IDcd0bb264c4d14fb6ad5a7e02e79ba7e5
AgencyDEPT OF DEFENSE
Sub-tierDEPT OF THE AIR FORCE
Contracting officeFA4528 5 CONS
NAICS code332420
Product / service code (PSC)5430
Set-asideTotal Small Business Set-Aside (FAR 19.5)
Notice typeCombined Synopsis/Solicitation
Posted08 July 2026
Response deadline16 July 2026 (closed)
Place of performanceMinot AFB, ND, USA

Description

Name: Oil/Coolant Storage and Dispenser Make: NOT A BRAND NAME SET-ASIDE Lubrisource or equal Model: HDL4-FS-0064-3W-2E-1F-1SP or equal The suggested brand name is Lubrisource; however, quotes for "equal" products will be evaluated and accepted provided they meet all the essential physical, functional, and performance characteristics System Configuration & Facility Requirements Must fit within a maximum space of 12ft W x 9ft D x 10ft H. (Dimensions may be adjusted if the design safely maximizes vertical space). Stackable, modular, or racked design. Must include brackets to hold the containers securely in 2 rows of 4. Must operate on Compressed Air Equipment delivery only. Contractors are NOT required to perform physical assembly, anchoring, or setup. Four (4) 120-Gallon aluminized steel, rectangular containers. (3) Black (1) Blue Tanks must feature sloped bottoms and drain ports for easy cleaning. Fluid Capacities & Coding System must be capable of holding a minimum of 275 Gallons of Oil (up to 15W-40 viscosity) and ES Compleat PG diluted 50/50 and 165 Gallons of Coolant. Tanks must be color-coded to clearly identify different fluids. Brands of each lubricant: Multiple sources, and Fleet Guard. Top-mounted desiccant breathers featuring visual "Color-Change" indicators. Sight gauges for visual monitoring of liquid levels. Gauges must include printed volume demarcations. Two (2) Pneumatic (Air-Operated), self-priming pumps with suction tube assemblies. One Gear/Piston Pump (dedicated to Oil) and one Double-Diaphragm (AODD) Pump (dedicated to Coolant). Two (2) 50ft Hose Reels (one for Oil, one for Coolant). Pumps must be strong enough to support the 50ft reels and intake/refill. Must include lockable dispensing ball valves. It must feature 10-micron inline filters prior to dispensing. Must include isolation valves installed before the filters for both coolant and oil to allow fluid shutoff during filter changes. Spill containment must hold a minimum of 130 Gallons (which satisfies the 25% of total liquid stored requirement). Drip pans must be included. (Drain valves on drip pans are not required). All sight gauges must have isolation valves installed to prevent leaks if the gauge glass is broken.

Go deeper on this solicitation

FedSift reads the full solicitation package — every attachment — and pre-extracts the compliance matrix, evaluation factors, key risks, win themes and deal-breakers, each with a verbatim quote and the exact PDF page it came from. It scores the opportunity against your company profile, tells you whether to bid as prime or sub, and ranks teaming partners who could close your gaps.

Open the AI analysis in FedSift →

Free forever plan — no credit card. Browse solicitations without an account; sign in for AI analysis and matching.

Other open solicitations in NAICS 332420

All NAICS 332420 solicitations →

More from DEPT OF DEFENSE

All DEPT OF DEFENSE solicitations →

Source: this notice on SAM.gov. FedSift republishes public federal procurement data and is not affiliated with the U.S. Government. Always confirm dates and requirements against SAM.gov before responding.