Solicitations
› VETERANS AFFAIRS, DEPARTMENT OF
› NAICS 334510
6515--Zoll Zenix Series Advanced Defibrillators Brand Name or Equal
VETERANS AFFAIRS, DEPARTMENT OF · Solicitation 36C24426Q0546 · NAICS 334510 · Unrestricted (full and open) · Closed
This solicitation has closed.
Responses were due 06 May 2026.
The record stays published because closed procurements are what a recompete is
built from — the follow-on is typically solicited 6–18 months before the
incumbent contract ends. Open solicitations like this one are linked below.
Solicitation details
| Solicitation number | 36C24426Q0546 |
|---|
| Notice ID | e21fd7d76f934e4ba0a10774ead066a0 |
|---|
| Agency | VETERANS AFFAIRS, DEPARTMENT OF |
|---|
| Sub-tier | VETERANS AFFAIRS, DEPARTMENT OF |
|---|
| Contracting office | 244-NETWORK CONTRACT OFFICE 4 (36C244) |
|---|
| NAICS code | 334510 |
|---|
| Product / service code (PSC) | 6515 |
|---|
| Set-aside | Unrestricted (full and open) |
|---|
| Notice type | Sources Sought |
|---|
| Posted | 01 May 2026 |
|---|
| Response deadline | 06 May 2026 (closed) |
|---|
| Place of performance | Wilmington, DE, USA |
|---|
Description
STATEMENT OF NEED Zoll Zenix Series Advanced Defibrillators INTRODUCTION/BACKGROUND: Wilmington VAMC requires modern, reliable hospital defibrillator/monitors to support advanced resuscitation and patient transport within the facility. The ZOLL Zenix platform (or equal) provides multi-parameter monitoring, defibrillation, pacing, CPR feedback, and data integration capabilities required for patient care. The following is being requested to be utilized by our two Rapid Response Teams in ICU and ED to respond to any code alerts within the main bldg. and outside bldg. areas. As of right now our outside bldgs. only have the capability to support AED only. With the Zoll Zenix series this is particularly suited for more advanced life support situation, and the compact size and weight make it easy for our Rapid Response Team to transport. Currently we have Zoll brand defibrillators R series on our emergency crash carts and all the necessary supplies which staff are already trained on. The Zoll Zenix has the same defib connection pads as our R series. PRODUCT/SPECIFICATIONS: SCOPE: The Department of Veterans Affairs, Wilmington VA Medical Center requests a brand name or equal procurement for the purchase of new Zoll Zenix Series Advanced Monitor/Defibrillator because it meets our needs for enhancing patient safety, accessibility, portability, and advanced monitoring capabilities. This is a brand name or equal for the following: Zoll Zenix. The following items are requested: Line No. Part No. Description Qty 001 8116-14-41-22331-00- USA Zenix Monitor/Defibrillator, Hospital, Ultimate CCT Configuration + 12L 12-Lead, Pacing, SpO2, EtCO2, NIBP, IBP/Temp, Real CPR Help, Real BVM Help - Includes: SurePower 4 Battery, Zenix Power Cord (NA), Zenix MFC Cable, Zenix 12-lead ECG Cable (AAMI), Zenix Accuvent Z-Link Cable, Masimo RD Rainbow SET Patient Cable, Masimo RD SET Adult Reuseable SpO2 Sensor, IRMA CO2 Analyzer, Zenix NIBP Patient Hose, Zenix NIBP Cuff (Reusable, Adult Plus), Zenix IBP Z-Link Cable (Abbott), Zenix Temperature Z-Link Cable, Zenix, Z-Fold Paper, Zenix MFC Self Test Plug Kit and Five (5)-year Hospital warranty. Parameter Details: Real CPR Help - Dashboard display of CPR Depth and Rate for Adult and Pediatric patients, Visual and audio prompts to coach CPR depth (Adult patient only), Release bar to ensure adequate release off the chest, Metronome to coach rate for Adult and Pediatric patients. See-Thru ® CPR artifact filtering 12-Lead ECG with Inovise Interpretative Algorithm (Full 12 ECG lead view with both dynamic and static 12-lead mode display. 12- Lead ECG cable - includes 4-Lead limb lead cable and removable precordial 6-Lead set) ZOLL Noninvasive Pacing Technology Real BVM Help: Dashboard provides real-time ventilation feedback on both volume and rate for intubated and non-intubated patients. AccuVent Z-Link Cable included. (Accuvent disposable sensors sold separately) SunTech NIBP technology. 10 foot single lumen hose and SunTech Reusable Adult Plus Cuff included Two Temperature monitoring channels with digital displays. One Temperature Z-Link cable included. Temperature probes sold separately 2 002 8016-000111-01 SurePower 4 Battery 1 003 8016-001000 SurePower 4 Charger Adapter 004 8000-001128 AccuVent Sensors, Box of 10 5 005 8000-010109 Masimo IRMA Airway Adapter Adult, Box of 25 5 006 8016-000120-01 Zenix OneStep Connector 2 007 8016-000860-08 Zenix Carry Case, Slim 2 008 8012-0206 12-lead ECG Simulator 1 009 8000-000878-01 Zenix Fan Fold Paper, Grid, Box of 10 5 Required specifications/all equivalents must meet the following: General Weight: 13.2 lbs. (5.99 kg) with battery Dimensions: 9.4 in (23.9 cm) x 10.3 in (26.2 cm) x 8.6 in (21.8 cm) Enclosure Protection: Solid foreign object: EN 60529, IP3X Water: EN 60529, IP3X Operating Temperature: 32 to 104°F (0 to 40°C) Transport and Storage Temperature: -4 to 41°F (-20 to 5°C) Humidity: 15 to 95% (non-condensing) Vibration: 60068-2-64 Shock: 60068-2-27, 50g, 6ms half sine Drop: IEC 60068-2-31, 18 in (0.5 meters) functional drop 60601, 78 in (2 meter) safety drop Altitude: -1,276 to 15,000 feet (-389 to 4,572 meters) Monitor/Display Size: 8.4 in (21 cm) diagonal Type: Color LCD 800 x 600 touchscreen Display: Up to 4 waveforms Defibrillator Waveform: Rectilinear Biphasic waveform Patient Population: Adult, pediatric, neonatal/infant Patient Impedance Range:15 to 300 ohms (hands-free electrodes or external paddles) 7 to 300 ohms (internal paddles) Energy Selections: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 30, 50, 70, 85, 100, 120, 150, 200 joules Charge Time: Less than 7 seconds with a new, fully charged battery at 77°F (25°C) for 15 successive charges Rapid Shock: Shock/No Shock decision with pre-charge of the device in 4 to 5 seconds Advisory Defibrillation: Shock Advisory Function prompts rescuers through ECG analysis, shocks and CPR throughout a rescue event. The ECG is analyzed with shock/no shock decision provided to rescuer. Pacer Type: External transcutaneous pacing Pulse Types: Rectilinear, constant current Pulse Width: 40 ms +/- 2 ms Pacer Rate: 30 - 180 PPM (+/- 1.5% for Fixed Mode) Output Current: 10 - 140 mA +/- 5% or 5 mA (whichever is greater) Minimum Pacer Output: 10 mA Modes: Demand, Fixed Output Protection: Fully defibrillator protected and isolated Cardioversion Synchronized defibrillator pulse to patients' R wave. "SYNC" message displayed on monitor and markers shown on both monitor and recorded ECG. Real-Time Clinical Feedback See-Thru CPR: See-Thru CPR: Removes compression-related artifact from the ECG via an adaptive filtering technique. Real CPR Help: Real-time depth and rate feedback. CPR Dashboard: Numeric readout of pediatric and adult depth and rate, release indicator, perfusion performance indicator (PPI). Real BVM Help: Provides ventilation feedback including rate and tidal volume in ml ECG Monitoring Input: 3-lead, 5-lead, 12-lead cables, paddles, therapy electrodes with MFC cable Lead Selections: Paddles, Pads, I, II, III, AVR, AVL, AVF, V1-V6. Heart Rate Range:20 - 300 beats/minute Heart Rate Accuracy:3 BPM or +/- 3%, whichever is greater ECG Size Range:0.25, 0.5, 1, 2, 3, 4 cm/mV ECG Sweep Speed: User selectable25 mm/sec or 50 mm/sec External Patient Monitor Connections ECG Output: 1.0V/cm of deflection on recorder; 4.0mm SPU Pediatric/neonatal/infant: 4.0mm Accuracy for all Conditions: +/-(0.3 kPa + 4% readings Respiration Rate: 0 to 150 +/- 1 breaths/minute Warm-Up Time: < 10 seconds (concentrations reported and full accuracy) Non-Invasive Blood Pressure Patient Population: Adult, pediatric Method: Oscillometry Control: Automatic and manual measurement Auto Mode Intervals: 1, 2, 3, 5, 10, 15, 30, 60 mins Masimo RD SET SpO SpO2 Saturation Range: 0 - 100% SpO2 Saturation Accuracy: No Motion: Adult/pediatric/infant: 70 - 100%, +/-2% Neonate: 70 - 100%, +/- 3% Motion: 70 - 100%, +/- 3% adults/pediatrics/infants/neonates SpO2 Pulse Rate Range: 25 - 240 beats/minute Masimo RD Rainbow Set SET Masimo rainbow SET SpCO: Range: 0 99% Accuracy: 1 40%, ± 3%, Adults/pediatrics/infants Masimo rainbow SET SpMet: Range: 0 99% Accuracy: 1 15%, ± 1%, Adults/pediatrics/infants/neonates Masimo rainbow SET SpHb: Range: 0 25 g/dL, 0-15.5 mmol/L,0-250 g/L Accuracy: 8-17 g/dL, 1 g/dL adults/pediatric Masimo rainbow SET SpOC: Range: 0 to 35 ml/dL Masimo Perfusion Index (PI): Range: 0.02% - 20% Masimo Pleth Variability Index (PVI): Range: 0.02% - 100% Patient Log Files Full Disclosure Data Storage: Contains continuous waveform data, treatment markers, CPR data, 12-lead snapshots, monitor snapshots, automatic snapshots, trend records and vital signs numeric updates. Full Disclosure Storage Capacity: Up to 150 patient cases with FIFO storage or to the maximum storage capability Printer / Recorder Type: High resolution thermal array Annotation: Snapshots, alarms, and treatment summaries Paper Width: 80 mm Paper Speed: 25mm and 50mm per seconds configurable Delay: 6 seconds Record Modes: Manual or automatic configurable Battery Type: Rechargeable lithium ion,10.8 Vdc, 8.61 Ah, 93 Wh Capacity: At least 4 hours of continuous monitoring with ECG, SpO2, CO2, three invasive pressure channels, two temperature channels, NIBP measurements every 15 minutes, wireless communication disabled, display brightness set to 10%, and volume set to medium (with a new, fully charged battery operating at room temperature) Weight: 1.5 lb. Recharge Time: 5 hours to fully charge, max. When charged by Zenix AC Power Adapter: 100 240 VAC 50-60 Hz, 160 VA External Data Transfer Data Transfer Port: USB (Type A and C), Wi-Fi, Bluetooth Monitor Port: Video Out Wi-Fi: 802.11 a, b, g, n and ac Bluetooth: 5.0 TRAINING: Must provide training for the rapid response teams, nurse educators and bio-med. DELIVERY: Delivery shall be within 90 days after receipt of contract. Deliver equipment to: Wilmington VA Medical Center (Attn: Shayonna Smith) 1601 Kirkwood Hwy Wilmington, DE 19805-4917 POINT OF CONTACT…
Go deeper on this solicitation
FedSift reads the full solicitation package — every attachment — and pre-extracts
the compliance matrix, evaluation factors, key risks, win themes and
deal-breakers, each with a verbatim quote and the exact PDF page it came from. It
scores the opportunity against your company profile, tells you whether to bid as
prime or sub, and ranks teaming partners who could close your gaps.
Open the AI analysis in FedSift →
Free forever plan — no credit card.
Browse solicitations without an account; sign in for AI analysis and matching.
Other open solicitations in NAICS 334510
All NAICS 334510 solicitations →
More from VETERANS AFFAIRS, DEPARTMENT OF
- 6640--Albany VAMC PLMS MALDI NEW CONTRACT FY 27 (VA-27-00006444)VETERANS AFFAIRS, DEPARTMENT OF · Due 13 September 2026
- Fort Sam Houston National Cemetery Tree Pruning Cascading EvaluationVETERANS AFFAIRS, DEPARTMENT OF · Due 13 September 2026
- Cardio-Pulmonary BoomsVETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- 6835-- BULK OXYGEN (Base+4 Option)VETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- Specimen Barcode Software Iowa City VAVETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- Dental Imaging Equipment- CS 9600, Radiographic Units, and sensor kitsVETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- Dental Imaging Equipment- CS 9600, Radiographic Units, and sensor kitsVETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- NEUROFORTIS NEUROSMART DRIVE HEADSTAGE KITVETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
All VETERANS AFFAIRS, DEPARTMENT OF solicitations →
Source: this notice on SAM.gov.
FedSift republishes public federal procurement data and is not affiliated with
the U.S. Government. Always confirm dates and requirements against SAM.gov
before responding.