Solicitations
› DEPT OF DEFENSE
› NAICS 335314
Sources Sought for SEL-387L
DEPT OF DEFENSE · Solicitation N6274226RSEL387L · NAICS 335314 · Unrestricted (full and open) · Closed
This solicitation has closed.
Responses were due 30 July 2026.
The record stays published because closed procurements are what a recompete is
built from — the follow-on is typically solicited 6–18 months before the
incumbent contract ends. Open solicitations like this one are linked below.
Solicitation details
| Solicitation number | N6274226RSEL387L |
|---|
| Notice ID | e226e9a9e8ce4c569fe80cbdbbdade25 |
|---|
| Agency | DEPT OF DEFENSE |
|---|
| Sub-tier | DEPT OF THE NAVY |
|---|
| Contracting office | NAVFACSYSCOM PACIFIC |
|---|
| NAICS code | 335314 |
|---|
| Product / service code (PSC) | 5945 |
|---|
| Set-aside | Unrestricted (full and open) |
|---|
| Notice type | Sources Sought |
|---|
| Posted | 28 July 2026 |
|---|
| Response deadline | 30 July 2026 (closed) |
|---|
| Place of performance | JBPHH, HI, USA |
|---|
Description
Notice of intent to use a brand name product. The Naval Facilities Engineering Systems Command, Pacific (NAVFAC Pacific) is performing a market survey to determine if other potential sources of supply can provide a transformer protection relay that has equal performance requirements as the SEL-387L, manufactured by Schweitzer Engineering Laboratories (SEL), 2350 NE Hopkins Court, Pullman, WA 99163. Fiscal Year 2027 SIOP PROJECT P-8026 ELECTRICAL BACKBONE Pearl Harbor Naval Shipyard and IMF Joint Base Pearl Harbor-Hickam, Hawaii, requires transformer protection relay that has equal performance requirements as the SEL-387L with the following characteristics: Line Differential Protection Protect transmission or distribution lines using current differential protection for high-speed clearing of internal line faults. Provide dual-slope differential elements with external fault security and communications-assisted protection for internal fault detection while maintaining stability during external faults. Backup Protection Provide comprehensive backup protection including phase, negative-sequence, and ground overcurrent elements, directional overcurrent elements, breaker failure protection, and configurable distance or permissive tripping functions as required for reliable line protection. Line Monitoring Monitor three-phase currents, voltages (when applicable), frequency, power, sequence quantities, and communications-assisted protection status. Provide fault location and disturbance analysis capabilities to support system operation and maintenance. Reporting and Monitoring Provide event reporting with sequential event recorder (SER), oscillographic event reports, fault records, and communications diagnostics to document faults, trips, currents, voltages, and relay operations for post-event analysis. Panel Control Switches Conveniently sized operator controls shall be located on the relay front panel and configured to track associated operator control functions, including breaker control, relay status, and programmable pushbutton operations. This notification is for market research purposes only to identify if other potential sources of supply can meet the requirements of the Government. This is not a request for proposals, quotes, or an invitation for bid. The intent of this notice is to identify other potential sources of this product. To be considered, please submit detailed technical data for the Government to conduct a comprehensive evaluation of your manufactured product to ensure compatibility with the existing system. In accordance with FAR 15.201(e), a response to this notice is not an offer and cannot be accepted by the Government to form a binding contract. The responder is solely responsible for the information it submits and any associated costs. The Government reserves the right to disregard any submittal that is incomplete or vague. Please do not submit company brochures. Please submit complete information via electronic mail to Ms. Annette Tijerina at annette.t.tijerina.civ@us.navy.mil no later than 30 July 2026 at 2:00 p.m. H.S.T. Any information received after the due date/time will not be considered. Any information provided to the Government in response to this RFI will become U.S. Government property and will not be returned. All proprietary or classified information will be treated appropriately.
Go deeper on this solicitation
FedSift reads the full solicitation package — every attachment — and pre-extracts
the compliance matrix, evaluation factors, key risks, win themes and
deal-breakers, each with a verbatim quote and the exact PDF page it came from. It
scores the opportunity against your company profile, tells you whether to bid as
prime or sub, and ranks teaming partners who could close your gaps.
Open the AI analysis in FedSift →
Free forever plan — no credit card.
Browse solicitations without an account; sign in for AI analysis and matching.
Other open solicitations in NAICS 335314
All NAICS 335314 solicitations →
More from DEPT OF DEFENSE
All DEPT OF DEFENSE solicitations →
Source: this notice on SAM.gov.
FedSift republishes public federal procurement data and is not affiliated with
the U.S. Government. Always confirm dates and requirements against SAM.gov
before responding.