Solicitations
› DEPT OF DEFENSE
› NAICS 238220
B706 HVAC Repair
DEPT OF DEFENSE · Solicitation RFQ-2026-HVAC-CH-50 · NAICS 238220 · No Set aside used · Closed
This solicitation has closed.
Responses were due 11 September 2026.
The record stays published because closed procurements are what a recompete is
built from — the follow-on is typically solicited 6–18 months before the
incumbent contract ends. Open solicitations like this one are linked below.
Solicitation details
| Solicitation number | RFQ-2026-HVAC-CH-50 |
|---|
| Notice ID | eafbe5bea7b446e5bcb32df6de5b315b |
|---|
| Agency | DEPT OF DEFENSE |
|---|
| Sub-tier | DEPT OF THE AIR FORCE |
|---|
| Contracting office | FA6648 482 LSS LGC |
|---|
| NAICS code | 238220 |
|---|
| Product / service code (PSC) | J041 |
|---|
| Set-aside | No Set aside used |
|---|
| Notice type | Presolicitation |
|---|
| Posted | 27 August 2026 |
|---|
| Response deadline | 11 September 2026 (closed) |
|---|
| Place of performance | Homestead, FL, USA |
|---|
Description
This notice is issued in accordance with the Revolutionary FAR Overhaul (RFO) Part 12, specifically RFO 12.102(a) (Restricting Competition) and RFO 5.101. The Government intends to award a Firm-Fixed-Price commercial construction contract on a sole source basis to PP91 Enterprises, Inc, (UEI: TK2SC8CCNUL4), an 8(a) small business. The Government has a requirement for the specialized mechanical and software re-configuration of the facility's existing HVAC System . The scope of work includes, but is not limited to: Re-programming and re-configuration of the chiller control sequences to align with updated building occupancy schedules. Integration of the mechanical piping and variable frequency drives (VFDs) between the chiller system and the ERU dampers. Testing, balancing, and commissioning of the combined HVAC/ERU loop to ensure optimal energy efficiency and air exchange metrics. Verification of compliance with building automation system (BAS) communication protocols. The Government intends to solicit and negotiate a sole-source contract with the Original Construction Contractor, for the following critical technical and warranty reasons: Warranty Integrity: The HVAC Chiller, air handlers, and ERU systems were recently installed by the Original Construction Contractor and are currently under an active, comprehensive installer and manufacturer warranty. Performing physical or software re-configuration through any third-party mechanical contractor would immediately void the remaining warranty, exposing the Government to significant financial liability for future system repairs or failures. Specialized Technical Familiarity: Having designed and built the mechanical integration of this facility, the Original Construction Contractor has unmatched technical familiarity with the custom piping geometry, flow dynamics, and specific electrical hookups of this site. Introducing a new vendor would require extensive duplicate diagnostics and system engineering, resulting in substantial duplicative costs and unacceptable delays. Response Instructions THIS NOTICE IS NOT A REQUEST FOR COMPETITIVE QUOTES. However, in accordance with RFO publicizing and simplified commercial guidelines, any responsible source that believes it can fully meet the Government s requirements may submit a capability statement, proposal, or quotation which shall be considered by the agency. All submissions must include: Company name, CAGE code, UEI, and socioeconomic status. A detailed technical narrative and supporting evidence demonstrating the vendor's ability to perform the HVAC re-configuration without voiding active manufacturer warranties or requiring proprietary programming keys. Pricing quote Responses must be submitted via email to the Contracting Officer no later than 11 September 2026 at 12:00 PM EST.
Go deeper on this solicitation
FedSift reads the full solicitation package — every attachment — and pre-extracts
the compliance matrix, evaluation factors, key risks, win themes and
deal-breakers, each with a verbatim quote and the exact PDF page it came from. It
scores the opportunity against your company profile, tells you whether to bid as
prime or sub, and ranks teaming partners who could close your gaps.
Open the AI analysis in FedSift →
Free forever plan — no credit card.
Browse solicitations without an account; sign in for AI analysis and matching.
Other open solicitations in NAICS 238220
- Backflow Preventer UpgradesDEPT OF DEFENSE · Due 14 September 2026
- B40 Heat pump ReplacementDEPT OF DEFENSE · Due 14 September 2026
- Y1DA--556-26-2-6953-0001 - 556-24-108 Double Block and Bleed Construction (VA-26-00035322)VETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- Y1DA--556-26-2-6953-0001 - 556-24-108 Double Block and Bleed Construction (VA-26-00035322)VETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- Z1DA--CON-NRM-668-26-103S Pharmacy Cache HVAC RepairVETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- FEMA Region 2 Naval Weapons Station Earle Building C-54 HVAC Rooftop Units Replacement and Mini Split Units for Server Room & WarehouseHOMELAND SECURITY, DEPARTMENT OF · Due 14 September 2026
- Inspect, test, repair, maintain, and ensure the operational readiness of all existing fire alarm systems, fire extinguishers, and backflow…COMMERCE, DEPARTMENT OF · Due 14 September 2026
- Z--WY-JACKSON NFH-GEOTHERMAL HVAC RPLCMNTINTERIOR, DEPARTMENT OF THE · Due 14 September 2026
All NAICS 238220 solicitations →
More from DEPT OF DEFENSE
All DEPT OF DEFENSE solicitations →
Source: this notice on SAM.gov.
FedSift republishes public federal procurement data and is not affiliated with
the U.S. Government. Always confirm dates and requirements against SAM.gov
before responding.