Solicitations
› DEPT OF DEFENSE
› NAICS 321991
TINY HOME
DEPT OF DEFENSE · Solicitation W911S226U2312 · NAICS 321991 · Small Business Set Aside - Total · Closed
This solicitation has closed.
Responses were due 14 January 2026.
The record stays published because closed procurements are what a recompete is
built from — the follow-on is typically solicited 6–18 months before the
incumbent contract ends. Open solicitations like this one are linked below.
Solicitation details
| Solicitation number | W911S226U2312 |
|---|
| Notice ID | 2bebda7ea5144d89b113aa62e0ba8d2e |
|---|
| Agency | DEPT OF DEFENSE |
|---|
| Sub-tier | DEPT OF THE ARMY |
|---|
| Contracting office | W6QM MICC-FT DRUM |
|---|
| NAICS code | 321991 |
|---|
| Product / service code (PSC) | 5450 |
|---|
| Set-aside | Small Business Set Aside - Total |
|---|
| Notice type | Combined Synopsis/Solicitation |
|---|
| Posted | 06 January 2026 |
|---|
| Response deadline | 14 January 2026 (closed) |
|---|
Description
Reason for amendment is to change the response date from 8 January 2026 to 15 January 2026 in order to allow additional time due to the holidays.Contractor shall provide a prebuilt modular home with a screened-in outdoor porch. Exterior dimensions not to exceed 13 feet 8 inched by 39 feet 7.inches Entrance to the building will be from the porch. Building to be built for 4-seasonuse. Building exterior shall include the following (final colors to be determined at a later date, shall be selected from manufacturers standard selection), Standing seam metal roof,5:12 pitch(with a factory applied finish), Engineered wood lap siding and trims, with textured finish and factory allied primer and finish, LED outdoor lighting near entryway, Insulated single hung low E vinyl windows without grid, Main entryway from porch to have lockable painted 6 panel steel entryway door with smart programmable smart lock, Provide electrical panel box in NEMA rated enclosure for 50 amp service, Insulated skirting, R11 or greater to be supplied along the building that will match building siding and will cover the underside of the building and span to grade. An access door is to be supplied on the skirting large enough to access the underbelly of the building. Building interior shall include the following: Kitchen to include 18 CF stainless steel refrigerator, full size gas range, space saver microwave, single bowl stainless steel drop-in sink, box-built cabinets with adjustable shelves, soft close dovetail drawers, 6-inch tile backsplash, and solid surface granite countertops (final finishes/colors to be determined at a later date, shall be selected from manufacturers standard selection), Full bathroom to include tile shower with glass door and shower road, china lavatory sink with metal faucets, 6-inch tile backsplash, elongated comfort height residential toilet, rainfall and handheld shower heads,and toilet paper holder and towel bar, 18k/24k fully electric split system unit for heating/cooling(one for master bedroom and one in living area, Interior walls and doors, sealed, 1.5 inch wood blinds throughout, 9-10 feet smooth finished ceiling, ? inch drywall with ? inch luan backer, ? inch vinyl plank flooring throughout(stock colors) Solid wood trim and moldings throughout, Furniture package to include sectional sofa for living area, single and double bed base and mattress for bunk room, queen bed base and mattress for master bedroom, and 42 inch wall mounted TV with swivel mounts in living area and master bedroom, Ceiling fan in living room centered with LED lights, Built in 4 drawer dressers in each bedroom, USBC outlets in each room, Nightstands on each side of bed in master bedroom, on demand gas water heater, Standard manifold plumbing system, Standard electrical package sufficient to power building appliances ? 50 amp service required, Deluxe overhead LED can lighting. Fire Protection Requirements: Provide all materials and equipment to include sprinkler system, fire alarm system, and perform all labor required to install complete and operable fire protection and health/safety systems incompliance with the most current editions of UFC 3-600-01, UFC 4-021-01, NFPA 13R,NFPA 24, NFPA 70, NFPA 72, NFPA 101, NFPA 90A, NFPA 10, and the additional standards referenced therein. General Design and Analysis: Provide a complete set of plans and specifications for all aspects of the fire protection design: This project requires the design, review, and oversight services of an FPE and as such the contractor is required to provide those services either directly or through a subcontract. The FPE shall be involved in every aspect of the design, construction, and testing/commissioning as it relates to fire protection and life safety. This includes, but is not limited to, building code analysis, life safety code analysis, design of automatic fire alarm, detection and suppression systems, water supply analysis, a multi-discipline review of the entire project, construction inspections and witnessing of fire protection acceptance testing/commissioning. The contractor shall submit with proposal, a written copy of the FPE resume indicating education, professional registration, and work experience, along with a letter attesting to their compliance with the requirements of this section. The letter must include an imprint of their professional engineering stamp with signature. Fire Protection Engineer Qualifications: The fire protection engineer of record shall be a registered professional engineer (P.E.) who has passed the fire protection engineering written examination administered by the National Council of Examiners for Engineering and Surveys (NCEES),with a minimum of 5 years experience, dedicated to fire protection engineering that can be verified with documentation. Evidence of qualifications shall be provided to the Government. In the design plans, include a fire protection design analysis, life safety plans, a code compliance summary sheet, code compliance site plan, and preliminary hydraulic analysis in accordance UFC 3-600-01. Final Design: The FPE must review the complete100 percent design drawings and specification submission (all disciplines) and document inwriting that the design complies with this UFC and all applicable fire protection and life safety design criteria. The review must provide verification that all items listed in the design analysis are correctly shown on the drawings and in the specification and list any approved equivalencies or deviations from this UFC. This design compliance document must be submitted prior to construction and must bear the signature and professional seal of the FPE. Fire Alarm and Detection Systems: Design and install fire alarm and mass notification systems as required to meet the required codes and standards. The design and installation shall be in accordance with UFC 3-600-01, UFC 4-021-01; NFPA 72, NFPA101, NFPA 90A, NFPA 13, UFGS 28 31 76, and the Fort Drum Utility Standard. These buildings are considered personnel housing and similar lodging facilities. The requirements of 4-37 and 4-43 of the fire protection UFC apply. The system shall be designed in accordance with the UFC and NFPA standards by personnel with the qualifications dictated in those standards and this statement of work. Submit prior to construction engineered and stamped construction plans and specifications for the fire alarm systems. Submit as a construction submittal the material and installation instructions for the suppression systems. All submittals for the fire detection and alarm system are for government review.The engineered and stamped construction plans and specifications will require a 15-business day review period versus the usual 10-day review. Incorporate the following paragraphs into the design and construction of the fire FA/MNS systems: The fire alarm and detection system shall be addressable. Fire alarm initiating devices, such as smoke detectors, heat detectors and manual pull stations shall be addressable. When the system is in alarm condition, the system shall annunciate the type and location of each alarm initiating device. Sprinkler water flow alarms shall be zoned by building and by floor. Supervisory alarm initiating devices, such as valve supervisory switches, fire pump running alarm, low-air pressure on dry sprinkler system, etc. shall be zoned by type and by room location. Install a new fire alarm and detection system including but not limited to a new control panel, annunciator, emergency lights, smoke detectors, heat detectors, carbon monoxide detectors, exit lights, audible and visual alarms, and gas detection/shut off. The fire alarm system will be an addressable, self-interrogation alarm/detection system with mass notification. Provide and install a non-proprietary fire alarm control panel such as Fire-Lite Alarms by Honeywell. Provide one panel to service all the buildings. Locate the panel in a temperature-controlled enclosure accessible from the outside of the buildings. Provide class A wiring. A new Monaco transmitter is required for these buildings. A single transmitter can be used for all the buildings and shall be located in a temperature controlled enclosure accessible from the exterior of the buildings. The installation uses Monaco BTX radio transmitter system and MNS. All signals shall be transmitted to the Fort Drum Fire Department fire alarm receiving station. The following applies to all fire alarm systems: Transmitter frequency will be 413.325 UHF. Co-ax cable shall be run from the transmitter to an antenna mounted on an outside wall with long radius conduits or pull boxes so the cable is not damaged. Locate antenna on an exterior wall adjacent to enclosure. Keep co-ax runs as short as possible. System shall be water tight. All alarm wiring shall be in conduit. Wiring from control panel to transmitter shall be 20 gauge. Fire alarm systems shall transmit a supervisory signal, alarm signal and general…
Go deeper on this solicitation
FedSift reads the full solicitation package — every attachment — and pre-extracts
the compliance matrix, evaluation factors, key risks, win themes and
deal-breakers, each with a verbatim quote and the exact PDF page it came from. It
scores the opportunity against your company profile, tells you whether to bid as
prime or sub, and ranks teaming partners who could close your gaps.
Open the AI analysis in FedSift →
Free forever plan — no credit card.
Browse solicitations without an account; sign in for AI analysis and matching.
Other open solicitations in NAICS 321991
All NAICS 321991 solicitations →
More from DEPT OF DEFENSE
All DEPT OF DEFENSE solicitations →
Source: this notice on SAM.gov.
FedSift republishes public federal procurement data and is not affiliated with
the U.S. Government. Always confirm dates and requirements against SAM.gov
before responding.