Solicitations
› DEPT OF DEFENSE
› NAICS 238220
Fire Suppression Backflow preventer
DEPT OF DEFENSE · Solicitation PANNGB26P0000038507 · NAICS 238220 · Total Small Business Set-Aside (FAR 19.5) · Closed
This solicitation has closed.
Responses were due 20 July 2026.
The record stays published because closed procurements are what a recompete is
built from — the follow-on is typically solicited 6–18 months before the
incumbent contract ends. Open solicitations like this one are linked below.
Solicitation details
| Solicitation number | PANNGB26P0000038507 |
|---|
| Notice ID | 2d64fac728be4aa585ac98144a2b0381 |
|---|
| Agency | DEPT OF DEFENSE |
|---|
| Sub-tier | DEPT OF THE ARMY |
|---|
| Contracting office | W7M9 USPFO ACTIVITY KSANG 184 |
|---|
| NAICS code | 238220 |
|---|
| Product / service code (PSC) | J012 |
|---|
| Set-aside | Total Small Business Set-Aside (FAR 19.5) |
|---|
| Notice type | Sources Sought |
|---|
| Posted | 09 July 2026 |
|---|
| Response deadline | 20 July 2026 (closed) |
|---|
| Place of performance | McConnell AFB, KS, USA |
|---|
Description
This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. The purpose of this sources sought is for market research to gain knowledge of potential sources for future needs including interested small business sources. This notice is for planning purposes only. All interested parties should respond. Kansas Air National Guard, McConnell AFB will soon be soliciting for a project for Backflow Preventer Upgrades. The work shall consist of removal of the five backflow preventer systems varying in size and purpose and the installation of five new backflow preventer systems, replacing the existing systems. The contractor will be responsible for removal, proper sizing, connections, installation of the new backflow preventers, testing/certifying, and when complete there will be no defects nor leaks. The project needs to include the following: Building 33, Southwest Bay 6-inch diameter Backflow Preventer System for Fire Suppression Remove the existing 6-inch diameter Fire Suppression Backflow Prevention System. Install a new 6-inch diameter Fire Suppression Backflow Prevention System. Testing of the newly installed 6-inch diameter Fire Suppression Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County. Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following: Backflow Prevention System s Installation Date Backflow Prevention System s Manufacture Backflow Prevention System s Model Backflow Prevention System s Serial Number Backflow Prevention System s Rebuild Kit Specifications Backflow Prevention System s Description Building 44, Room 122, South wall 4-inch diameter Backflow Preventer System for Fire Suppression and Double Check Valve Remove the existing 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System. Install a new 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System. Testing of the newly installed 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County. Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following: Backflow Prevention System s Installation Date Backflow Prevention System s Manufacture Backflow Prevention System s Model Backflow Prevention System s Serial Number Backflow Prevention System s Rebuild Kit Specifications Backflow Prevention System s Description Building 44, Room 118, Interior, Southeast wall 1-inch diameter Backflow Preventer System for Boiler Makeup Remove the existing 1-inch diameter Boiler Makeup Backflow Prevention System. Install a new 1-inch diameter Boiler Makeup Backflow Prevention System. Testing of the newly installed 1-inch diameter Boiler Makeup Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County. Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following: Backflow Prevention System s Installation Date Backflow Prevention System s Manufacture Backflow Prevention System s Model Backflow Prevention System s Serial Number Backflow Prevention System s Rebuild Kit Specifications Backflow Prevention System s Description Building 48, Room 107, East wall 4-inch diameter Backflow Preventer System for Fire Suppression Remove the existing 4-inch diameter Fire Suppression Backflow Prevention System. Install a new 4-inch diameter Fire Suppression Backflow Prevention System. Testing of the newly installed 4-inch diameter Fire Suppression Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County. Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following: Backflow Prevention System s Installation Date Backflow Prevention System s Manufacture Backflow Prevention System s Model Backflow Prevention System s Serial Number Backflow Prevention System s Rebuild Kit Specifications Backflow Prevention System s Description Building 65, Room 154, Interior, South 2.5-inch diameter Backflow Preventer System for domestic water Remove the existing 2.5-inch diameter domestic water Backflow Prevention System. Install a new 2.5-inch diameter domestic water Backflow Prevention System. Testing of the newly installed 2.5-inch diameter domestic water Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County. Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following: Backflow Prevention System s Installation Date Backflow Prevention System s Manufacture Backflow Prevention System s Model Backflow Prevention System s Serial Number Backflow Prevention System s Rebuild Kit Specifications Backflow Prevention System s Description For this requirement, the small business size standard is $19 million for NAICS 238220. In the event small business In the event small business contractors are not avaialble for adequate competition for this project, it may be advertised as unrestricted. Please advise on your capabilities and or past perfromance in terms of the project requested and respond with a completed sources sought response form. Include the following email subject line "Fire Suppression Backfow Preventer Upgrades" when emailing 184WG.MSG.CONTRACTING@us.af.mil. Use the same address if you have additional questions. Attachments: 1. Statement of Work 2. Sources Sought Response Form
Go deeper on this solicitation
FedSift reads the full solicitation package — every attachment — and pre-extracts
the compliance matrix, evaluation factors, key risks, win themes and
deal-breakers, each with a verbatim quote and the exact PDF page it came from. It
scores the opportunity against your company profile, tells you whether to bid as
prime or sub, and ranks teaming partners who could close your gaps.
Open the AI analysis in FedSift →
Free forever plan — no credit card.
Browse solicitations without an account; sign in for AI analysis and matching.
Other open solicitations in NAICS 238220
- Backflow Preventer UpgradesDEPT OF DEFENSE · Due 14 September 2026
- B40 Heat pump ReplacementDEPT OF DEFENSE · Due 14 September 2026
- Y1DA--556-26-2-6953-0001 - 556-24-108 Double Block and Bleed Construction (VA-26-00035322)VETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- Y1DA--556-26-2-6953-0001 - 556-24-108 Double Block and Bleed Construction (VA-26-00035322)VETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- Z1DA--CON-NRM-668-26-103S Pharmacy Cache HVAC RepairVETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- FEMA Region 2 Naval Weapons Station Earle Building C-54 HVAC Rooftop Units Replacement and Mini Split Units for Server Room & WarehouseHOMELAND SECURITY, DEPARTMENT OF · Due 14 September 2026
- Inspect, test, repair, maintain, and ensure the operational readiness of all existing fire alarm systems, fire extinguishers, and backflow…COMMERCE, DEPARTMENT OF · Due 14 September 2026
- Z--WY-JACKSON NFH-GEOTHERMAL HVAC RPLCMNTINTERIOR, DEPARTMENT OF THE · Due 14 September 2026
All NAICS 238220 solicitations →
More from DEPT OF DEFENSE
All DEPT OF DEFENSE solicitations →
Source: this notice on SAM.gov.
FedSift republishes public federal procurement data and is not affiliated with
the U.S. Government. Always confirm dates and requirements against SAM.gov
before responding.