MT. SAINT HELENS HVAC REPLACEMENT UNIT BUILDING #1106
AGRICULTURE, DEPARTMENT OF · Solicitation 1240BD26Q0090 · NAICS 238220 · Small Business Set Aside - Total · Closed
This solicitation has closed.
Responses were due 03 September 2026.
The record stays published because closed procurements are what a recompete is
built from — the follow-on is typically solicited 6–18 months before the
incumbent contract ends. Open solicitations like this one are linked below.
Solicitation details
| Solicitation number | 1240BD26Q0090 |
|---|
| Notice ID | 38bc2012cd4a466fae13ed0791a1e76f |
|---|
| Agency | AGRICULTURE, DEPARTMENT OF |
|---|
| Sub-tier | FOREST SERVICE |
|---|
| Contracting office | GIFFORD PINCHOT NATIONAL FOREST |
|---|
| NAICS code | 238220 |
|---|
| Product / service code (PSC) | N045 |
|---|
| Set-aside | Small Business Set Aside - Total |
|---|
| Notice type | Combined Synopsis/Solicitation |
|---|
| Posted | 24 August 2026 |
|---|
| Response deadline | 03 September 2026 (closed) |
|---|
| Place of performance | Amboy, WA, USA |
|---|
Description
THE SOLICITATION IS AMENDED TO ADD A SITE VISIT THIS WEDNESDAY 8/26/26 FOR 1 HOUR WINDOW FROM 10:00 AM TO 11:00 AM. ALL ELSE REMAINS THE SAME. THERE IS MORE INFORMATION ON THE ATTACHED AMENDMENT. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12. This announcement constitutes the only solicitation; offers are being requested, and a separate written solicitation will not be issued. This contract involves the supply and installation of a replacement (single phase power) complete Heat pump system at Mount St Helens National Volcanic Monument Ranger District Office located in Amboy, WA. The existing HVAC system in place will need to be removed and disposed of (off site and off Forest Service Property) by the contractor. The current system is a has failed and needs replacement. Pictures are in the attachment. The contractor shall provide all labor and materials to replace the HVAC system along with all electrical connections by a license electrician. All work shall be performed in accordance with all applicable codes, and standards (OSHA, NEC, NFPA, ASHRAE). The contractor will replace the old unit with new units and make all necessary electrical connections to make the new units work. All units will be tested by the contractor. All electrical work is included in the quote. Amboy, WA routinely sees sustained winter temperatures below 25 degrees Fahrenheit. The replacement HVAC system must operate efficiently below 25 degrees. Emergency or electric strip heating is not allowed to be the sole source to achieve operations in these temperatures. Clearly state in the proposal summary the type, size, model number, and lower temperature rating of the equipment to be installed. Provide a brochure of the unit that your company will be providing for this contract. If you fail to provide a full brochure, your company will not be evaluated for award. Solicitation number 1240BD26Q0090 is issued as a Request for Quotation (RFQ). The applicable North American Industry Classification Standard Code is 238220. The small business size standard is $19.0 Million. This acquisition is a Total Small Business Set-Aside. All responsible sources may submit a quotation which will be considered by the agency. The Service code is N045 installation of equipment- plumbing, heating, and waste disposal equipment. The contract will be a Firm-Fixed Price contract. Address technical questions for this project to Melissa Jolley at (509) 310-3117 or email melissa.jolley@usda.gov Address contracting questions to Contracting Officer Jorge Somoza at (509) 423-2224. Email jorge.somoza@usda.gov Sent your quote by email to jorge.somoza@usda.gov only. do not send your quote to anyone else. Submit your quote no later than 03 September 2026 before 2:00 PM PDST. Any quote received after 2:00 PM on that day is late and it won t be accepted it.
Go deeper on this solicitation
FedSift reads the full solicitation package — every attachment — and pre-extracts
the compliance matrix, evaluation factors, key risks, win themes and
deal-breakers, each with a verbatim quote and the exact PDF page it came from. It
scores the opportunity against your company profile, tells you whether to bid as
prime or sub, and ranks teaming partners who could close your gaps.
Open the AI analysis in FedSift →
Free forever plan — no credit card.
Browse solicitations without an account; sign in for AI analysis and matching.
Other open solicitations in NAICS 238220
- Backflow Preventer UpgradesDEPT OF DEFENSE · Due 14 September 2026
- B40 Heat pump ReplacementDEPT OF DEFENSE · Due 14 September 2026
- Y1DA--556-26-2-6953-0001 - 556-24-108 Double Block and Bleed Construction (VA-26-00035322)VETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- Y1DA--556-26-2-6953-0001 - 556-24-108 Double Block and Bleed Construction (VA-26-00035322)VETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- Z1DA--CON-NRM-668-26-103S Pharmacy Cache HVAC RepairVETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- FEMA Region 2 Naval Weapons Station Earle Building C-54 HVAC Rooftop Units Replacement and Mini Split Units for Server Room & WarehouseHOMELAND SECURITY, DEPARTMENT OF · Due 14 September 2026
- Inspect, test, repair, maintain, and ensure the operational readiness of all existing fire alarm systems, fire extinguishers, and backflow…COMMERCE, DEPARTMENT OF · Due 14 September 2026
- Z--WY-JACKSON NFH-GEOTHERMAL HVAC RPLCMNTINTERIOR, DEPARTMENT OF THE · Due 14 September 2026
All NAICS 238220 solicitations →