FedSift

SolicitationsAGRICULTURE, DEPARTMENT OFNAICS 238220

Fire suppression system installation

AGRICULTURE, DEPARTMENT OF · Solicitation 12639526Q0210 · NAICS 238220 · Small Business Set Aside - Total · Closed

Solicitation details

Solicitation number12639526Q0210
Notice ID54fff48f924f496183a25e565ee92909
AgencyAGRICULTURE, DEPARTMENT OF
Sub-tierANIMAL AND PLANT HEALTH INSPECTION SERVICE
Contracting officeMRPBS MINNEAPOLIS MN
NAICS code238220
Product / service code (PSC)Y1JZ
Set-asideSmall Business Set Aside - Total
Notice typeCombined Synopsis/Solicitation
Posted21 August 2026
Response deadline25 August 2026 (closed)
Place of performanceEdinburg, TX, USA

Description

Due to a recent fire in building 6418 at Moore Air Base, Texas, a wet fire suppression system is needed. Building 6418 was constructed in the early 1980s with no fire suppression initially. Contractor shall provide design/as-built drawings submittals and installation of a new retrofitted system. The system shall be a turnkey project encompassing everything needed to have a fully functioning fire suppression system. Solicitation documents are posted below. NOTE: For those wishing to attend the site visit, please send names of attendees to james.g.roloff@usda,gov. A valid drivers license or state ID is required. Amendment 1 is posted below. RFI: Does Building 6418 currently have an existing fire alarm panel/system that the sprinkler monitoring would tie into? If so, could you please provide the panel/system type, make/model, or any available details needed for a sprinkler monitoring quote? The fire panels are old and obsolete. They will be replaced at another time, but the new sprinkler system must be able to connect to a fire panel in the future. No monitoring is needed. The sign-in sheet for the site visit is posted below. Building drawings posted below. RFIs and responses posted below. Amendment 2 is posted below. It extends the closing date. Amendment 3 is posted below. It extends the closing date. Additional RFIs and responses posted below. Amendment 4 is posted below. There's a change to the response to RFI 6 posted here on August 17. The correct answer is as follows: 6) Please confirm if a CVPC/PEX fire suppression would be sufficient or the USDA prefers schedule 10 or schedule 40 Victaulic black iron piping? Or provide a specification with minimum standards for Moore Airfield that must be met regarding fire suppression piping? It is typical for local building codes and state codes to be of a lesser standard than what a federal installation requires. The statement of work indicates in accordance state and local codes and standards only opening the door for a CVPC system to be priced. The USDA prefers the use of Schedule 40 Victaulic black iron piping.

Go deeper on this solicitation

FedSift reads the full solicitation package — every attachment — and pre-extracts the compliance matrix, evaluation factors, key risks, win themes and deal-breakers, each with a verbatim quote and the exact PDF page it came from. It scores the opportunity against your company profile, tells you whether to bid as prime or sub, and ranks teaming partners who could close your gaps.

Open the AI analysis in FedSift →

Free forever plan — no credit card. Browse solicitations without an account; sign in for AI analysis and matching.

Other open solicitations in NAICS 238220

All NAICS 238220 solicitations →

More from AGRICULTURE, DEPARTMENT OF

All AGRICULTURE, DEPARTMENT OF solicitations →

Source: this notice on SAM.gov. FedSift republishes public federal procurement data and is not affiliated with the U.S. Government. Always confirm dates and requirements against SAM.gov before responding.