FedSift

SolicitationsVETERANS AFFAIRS, DEPARTMENT OFNAICS 238220

J012--Fire Sprinkler Repairs

VETERANS AFFAIRS, DEPARTMENT OF · Solicitation 36C26226Q0654 · NAICS 238220 · Service-Disabled Veteran-Owned Small Business Set Aside · Closed

Solicitation details

Solicitation number36C26226Q0654
Notice ID80877120a98e4da28fe10fbc86adff2c
AgencyVETERANS AFFAIRS, DEPARTMENT OF
Sub-tierVETERANS AFFAIRS, DEPARTMENT OF
Contracting office262-NETWORK CONTRACT OFFICE 22 (36C262)
NAICS code238220
Product / service code (PSC)J012
Set-asideService-Disabled Veteran-Owned Small Business Set Aside
Notice typeSources Sought
Posted05 June 2026
Response deadline19 June 2026 (closed)
Place of performanceTucson

Description

Page 1 of 14 Page 12 of 12 Page 1 of 14 STATEMENT OF WORK CONTRACT TITLE: Fire Sprinkler repairs PLACE OF PERFORMANCES: VA San Diego Healthcare System 3350 La Jolla Village Dr. San Diego, CA 92161 PERIOD OF PERFORMANCE: 07/01/2026-06/30/2027 CONTRACT TYPE: Firm Fixed Price BACKGROUND: Fire sprinkler deficiencies from 2025 annual inspection and testing. GENERAL REQUIREMENTS: Per applicable VA San Diego requirements/standards, the contractor will: BLDG 1 WETPIPE REQUIRED REPAIRS: **** 6TH FLOOR **** NORTH: The following areas were found to have 50yr old sprinklers: 6231 (2), 6232 (2), 6233A (2), 6242 (2), 6239 (2), 6240, 6233 (2), 6243 (2), 6254 (6), 6245 (2), 6246 (4), 6246A (2), 6230 (4), 6252B (2), 6252C (1), 6252E (4), 6247 (2), 6249 (2), 6250 (1), 6251 (1), 6254 (6), 6254A (2), 6256 (2), 6257 (2), 6264 (1), 6254B (2), 6263 (2), 6267 (6), 6268 (1), 6269 (2), 6259 (2),6263A (1), 6224 (1), 6225 (1), 6219 (2), 6218 (2), 6217 (4), 6215 (1), 6268 (2). Replace (88) 165° STD ½ Chrome SSP 401chrome trim. WEST: The following areas were found to have 50yr old sprinklers: 6097 (1), 6024 (1), 6035 (4), 6025 (2), 6032 (2), 6030(4), 6070 (1), 6029 (2), 6083 (2), 6082 (2), 6050 (1), 6045 (2), 6080 (1), 6081 (14), 6062 (3), 6048 (2), 6051 (2), 6049 (2), 6052(5), 6055 (3), 6058 (2), 6061 (2), 6056A (2), 6069 (2), 6074 (2), 6086 (2), 6087 (2), 6088 (4), 6095 (2), 6096 (2), 6091 (1), 6091A(1). Replace (82) 165° STD ½ chrome SSP 401 chrome trim. SOUTH: The following areas were found to have 50yr old sprinklers: 6105 (3), 6107 (4), 6110 (4) 6118 (2), 6112 (1). Replace(14) 165° STD ½ chrome SSP 401 chrome trim. EAST: The following areas were found to have 50yr old sprinklers: 6149 (1), 6150 (4), 6153 (2), 6160 (1), 6163 (2), 6164 (4),6169 (2), 6170 (2), 6171 (2), 6172 (2), 6176 (2), 6174C (3), 6174G (4), 6174F (4), 6184 (2), 6189A (3), 6189C (2), 6187 (1), 6190(1), 6191 (2), 6192 (2), 6197 (1), 6198 (2) , 6200 (3), 6202 (2), 6203 (2), 6204 (2), 6205 (2), 6207 (2). Replace (66) 165° STD ½ chrome SSP 401 chrome trim. CORE: Housekeeping closet 6010 replace (1) corroded 155° QR ½ chrome SSP SRC trim. NORTH: 6254B replace (2) 20yr old 155° QR ½ chrome SSP 399 chrome trim (2001). NORTH: 6252A next to cage washer door replace (1) corroded 200° QR ½ chrome SSP 401 Chrome trim. NORTH: 6268 replace (2) 20yr old 155° QR ½ chrome SSP 401 chrome trim (2001). WEST: refrigerator 6037 replace (2) 20yr old 200° QR 1 x 12 chrome dry pendant w/ chrome trim (2002). NOTE: This will require majority stitch work. WEST: 6028 replace (2) loaded/corroded 155° QR ½ chrome SSP 401 chrome trim. WEST: 6044A in 6043 replace (1) corroded 155° QR ½ white SSP SRW. WEST: 6044 entry replace (1) corroded 155° QR ½ white SSP SRW. WEST: 6040 women s bathroom shower replace (1) corroded 155° STD ½ chrome SSP 401 chrome. WEST: refrigerator 6081E replace (1) 10yr old 200° STD 1 x 12 chrome dry pendant w/ chrome trim (2013). NOTE: this will require majority stitch work. WEST: 6070 refrigerator replace (1) 10yr old 200° STD 1 x 12 chrome dry pendant w/ chrome trim (2013). NOTE: this will require majority stitch work. WEST: 6056A & 6057 replace (2) 20yr old 155° QR ½ chrome SSP SRC trim (2001). WEST: 6062 replace (3) 20yr old 155° QR ½ chrome SSP 401 chrome trim (2002). WEST: 6070 replace (1) 20yr old 155° QR ½ white SSP SRW trim (2004). WEST: 6091 & 6091A replace (2) 20yr old 155° QR ½ chrome SSP 401 chrome trim (2002). SOUTH: 6104 refrigerator replace (1) 10yr old 200° STD 1 x 12 chrome dry pendant w/ chrome trim (2013). NOTE: this will require majority stitch work. SOUTH: 6108A replace (4) corroded 165° STD ½ chrome SSP 401 chrome trim. SOUTH: 6112 replace (1) 20yr old 155° QR ½ chrome SSP 401 chrome trim (2005). SOUTH: 6112 refrigerator replace (1) 10yr old 200° STD 1 x 12 chrome dry pendant w/ chrome trim (2013) this will require majority stitch work. NOTE: Inside refrigerator is very warm! EAST: hallway leading to stair 12 replace (9) corroded 155° STD ½ white SSP 401 white trim. EAST: 6155 replace (2) corroded 165° STD ½ chrome SSP 401 chrome trim. EAST: refrigerator 6166 replace (2) 10yr old 200° QR 1 x 12 chrome dry pendant w/ chrome trim (2013). NOTE: this will require majority stitch work. EAST: 6179 replace (2) corroded 165° STD ½ chrome SSP 401 chrome trim EAST: 6197A in 6198 replace (3) corroded 165° STD ½ chrome SSP 401 chrome trim **** 5TH FLOOR **** SOUTH: exterior core hallway from stair 11 to dead end into east wing replace (7) corroded 155° QR ½ White SSP 401 white trim. NORTH: exterior core hallway to stair 9 replace (5) corroded 155° QR ½ white SSP 401 white. These Sprinklers are also near 20yrs old (2008). NORTH: hallway outside 5315 replace (1) corroded 155° QR ½ chrome SSP SRC trim. WEST: 5004 next to 5003 men s bathroom replace (2) corroded 155° QR ½ chrome SSP 401 chrome Trim. CORE: hallway to south wing door replace (4) 20yr old 155° QR ½ chrome SSP SRC trim. CORE: 5019 replace (1) 20yr old 155° QR ½ chrome SSP SRC trim. CORE: 5020 replace (9) 20yr old 155° QR ½ chrome SSP SRC trim. CORE: 5006 (2), 5005 (2), 5021 (1), 5010 (1), women s restroom (2), 5008 (6). Replace (14) 20yr old 155° QR ½ chrome SSP 401 chrome trim. NORTH: 5280 replace (6) 20yr old 155° QR ½ chrome SSP 401 chrome trim. NORTH: 5284 area and hallways replace (20) 20yr old 155° QR ½ chrome SSP SRC trim. NORTH: 5341 replace (1) 20yr old 155° QR ½ chrome HSW 401 chrome trim. NORTH: Vascular Lab area and hallways replace (61) 20yr old 155° QR ½ chrome SSP SRC trim. NORTH: ASU area replace (72) 20yr old 155° QR ½ chrome SSP SRC trim & (7) 20yr old 155° QR ½ chrome SSP 401 chrome trim. EAST: east wing hallway and rooms replace (36) 20yr old 155° QR ½ chrome SSP 401 chrome trim. EAST: C Pod replace (22) 20yr old 155° QR ½ chrome SSP 401 chrome trim . EAST: B Pod replace (18) 20yr old 155° QR ½ chrome SSP 401 chrome trim. EAST: B Pod in room 5219 replace (2) 20yr old 155° QR ½ chrome HSW 401 chrome trim. SOUTH: 5106B (1), 5126 (1), 5106A (1). Replace (3) 20yr old 155° QR ½ chrome SSP 401 chrome Trim. SOUTH: 5104 replace (4) 20yr old 155° QR ½ chrome SSP SRC trim. SOUTH: 5140 replace (4) 20yr old 155° QR ½ chrome SSP SRC trim. SOUTH: 5105 replace (2) 20yr old 155° QR ½ chrome SSP SRC trim. SOUTH: hallway from nurse station C to room 7 replace (40) 20yr old 155° QR ½ chrome SSP SRC trim. SOUTH: entrance to reception desk replace (7) 20yr old 155° QR ½ chrome SSP SRC trim. SOUTH: Nurses station A replace (18) 20yr old 155° QR ½ chrome SSP SRC trim. SOUTH: DOU area & patient rooms (31), staff office area (33). Replace (64) 20yr old 155° QR ½ chrome SSP SRC trim. EAST: 5244 bathroom replace (1) corroded 155° QR ½ chrome SSP 401 chrome trim. EAST: 5229 house keeping replace (1) missing Victaulic SRC trim. WEST: throughout Anesthesia/Surgery replace (128) 20yr old 155° QR ½ chrome SSP 401 chrome Trim & (56) 20yr old 155° QR ½ chrome SSP SRC trim. NOTE: Work to be completed at night. **** 4TH FLOOR **** SOUTH: 4329 replace (1) painted 155° QR ½ chrome SSP 401 chrome trim SOUTH: 4004 women s bathroom replace (1) corroded 155° QR ½ chrome SSP 401 chrome trim SOUTH: 4108 room #7 replace (3) corroded 155° QR ½ chrome SSP (1) SRC trim & (2) 401 chrome Trim NORTH: 4284 in 4289 exam room replace (1) corroded 155° QR ½ chrome SSP 401 chrome Trim NORTH: 4026 EP holding room replace (1) corroded 155° QR ½ white SSP SRW trim WEST: 4040 Specialty a clinic in 4045 clean linen replace (1) Victaulic SRC trim WEST: in 4071 Nuclear Medicine Hallway outside staff bathroom 4054 replace (1) corroded 155° QR ½ chrome SSP 401 chrome trim EAST: 4184B there are (2) sprinkler under 6 of each other in a cold solder situation. Need to relocate One sprinkler. SOUTH: 4124 room #16 replace (4) corroded 155° QR ½ chrome SSP (1) SRC trim & (3) 401 Chrome trim. SOUTH: 4113 room #12 replace (3) corroded 155° QR ½ chrome SSP (1) SRC trim & (2) 401 chrome Trim. SOUTH: 4115 meditation room replace (2) corroded 155° QR ½ chrome SSP SRC trim. SOUTH: 4162 conference room replace (2) corroded 155° QR ½ chrome SSP SRC trim. SOUTH: 4122 room #14 replace (2) corroded 155° QR ½ chrome SSP (1) SRC trim & (1) 401 chrome Trim. SOUTH: 4123 room #15 replace (4) corroded 155° QR ½ chrome SSP (1) SRC trim & (3) 401 Chrome trim. SOUTH: hallway outside 4123 & 4124 replace (2) corroded 155° QR ½ chrome SSP SRC trim. CORE: 4000A (2), 4008 (7), 4006 (2), 4005 (1). replace (12) 20yr old 155° QR ½ chrome SSP 401 Chrome trim. CORE: 4016 replace (5) 20yr old 155° QR ½ chrome SSP 401 chrome trim. CORE: 4015 (9), 4015A (2) replace (11) 20yr old 155° QR ½ chrome SSP SRC trim. NORTH: 4366 (11), 4370 (1), 4303 (2), 4304 (5), main hallway (13), Exam rooms 12-21 & hall Way (32), exam rooms 1-11 & hallway (34). replace (98) 20yr old 155° QR ½ chrome SSP 401 chrome SSP 401 chrome trim. EAST: 4263 surgical service Annex replace (39) 20yr old 155° QR ½ chrome SSP 401 chrome trim. EAST: 4186 nursing service replace (34) 20yr old 155° QR ½ chrome SSP 401 chrome trim. EAST: ELT area…

Go deeper on this solicitation

FedSift reads the full solicitation package — every attachment — and pre-extracts the compliance matrix, evaluation factors, key risks, win themes and deal-breakers, each with a verbatim quote and the exact PDF page it came from. It scores the opportunity against your company profile, tells you whether to bid as prime or sub, and ranks teaming partners who could close your gaps.

Open the AI analysis in FedSift →

Free forever plan — no credit card. Browse solicitations without an account; sign in for AI analysis and matching.

Other open solicitations in NAICS 238220

All NAICS 238220 solicitations →

More from VETERANS AFFAIRS, DEPARTMENT OF

All VETERANS AFFAIRS, DEPARTMENT OF solicitations →

Source: this notice on SAM.gov. FedSift republishes public federal procurement data and is not affiliated with the U.S. Government. Always confirm dates and requirements against SAM.gov before responding.