HVAC System Replacement and Upgrade/Refrigerated Air Conversion
AGRICULTURE, DEPARTMENT OF · Solicitation 127EAX26Q0031 · NAICS 238220 · Total Small Business Set-Aside (FAR 19.5) · Closed
This solicitation has closed.
Responses were due 26 June 2026.
The record stays published because closed procurements are what a recompete is
built from — the follow-on is typically solicited 6–18 months before the
incumbent contract ends. Open solicitations like this one are linked below.
Solicitation details
| Solicitation number | 127EAX26Q0031 |
|---|
| Notice ID | 8819c1307014414daae28d2004603965 |
|---|
| Agency | AGRICULTURE, DEPARTMENT OF |
|---|
| Sub-tier | FOREST SERVICE |
|---|
| Contracting office | LINCOLN NATIONAL FOREST |
|---|
| NAICS code | 238220 |
|---|
| Product / service code (PSC) | N045 |
|---|
| Set-aside | Total Small Business Set-Aside (FAR 19.5) |
|---|
| Notice type | Combined Synopsis/Solicitation |
|---|
| Posted | 17 June 2026 |
|---|
| Response deadline | 26 June 2026 (closed) |
|---|
| Place of performance | Ruidoso, NM, USA |
|---|
Description
*****************UPDATE 6-17-2026************************ Please note that a BID BOND IS REQUIRED with a quote package in accordance with FAR 28.101-1 (a): A contracting officer shall not require a bid guarantee unless a performance bond or a performance and payment bond is also required (see 28.102 and 28.103). Except as provided in paragraph (c) of this subsection, bid guarantees shall be required whenever a performance bond or a performance and payment bond is required. Since the Solicitation is marked Yes in box 12a requiring performance and payment binds, and the FAR Clause 52.228-15 Performance and Payment Bonds-Construction (Jun 2020) is included in the Solicitation, BID BONDS ARE ALSO REQUIRED. Please submit appropriate bid bonds as required for a complete and valid quote submission package. *****************UPDATE 6-17-2026************************ Amendment 001 with Request for Information questions & responses is now in the Attachments. This Amendment must be signed and acknowledged and included in any quote submission packages. ******************UPDATE 6-10-2026************************ DUE TO FIRE SEASON, FOREST SERVICE PERSONEL HAS NOT BEEN ABLE TO RESPOND TO ALL THE RFI QUESTIONS AS OF TODAY. EXTENDING THE QUOTE PACKAGE DUE DATE TO 6-26-2026 AT 12:00pm MOUNTAIN TIME. ONCE RFI RESPONSES ARE POSTED HERE, THE FOREST SERVICE WILL ENSURE THERE WILL BE 7 DAYS TO SUBMIT QUOTE PACKAGES, BUT WILL NOT BE SOONER THAN 6-26-2026. *************************************************************** The existing HVAC systems serving facilities at the Smokey Bear Ranger District have sustained significant operational degradation due to wildfire impacts and subsequent water intrusion, resulting in compromised indoor air quality, reduced system reliability and increased risk of equipment failure. This project proposes full replacement and upgrade to HVAC systems to restore safe, functional and compliant building operations. During recent wildfire events airborne ash and fine particulate matter infiltrated multiple buildings and mechanical systems. Ash accumulation has been documented within ductwork and air handling components The USDA Forest Service requires construction and mechanical services to replace and upgrade heating, ventilation and air conditioning (HVAC) systems at multiple facilities within the Smokey Bear Ranger District, Lincoln National Forest, Ruidoso NM. The requirement includes removal of existing systems, installation of new refrigerated HVAC systems, repair or replacement of associated ductwork, and upgrades to controls and distribution systems as necessary to support reliable year-round building operations.
Go deeper on this solicitation
FedSift reads the full solicitation package — every attachment — and pre-extracts
the compliance matrix, evaluation factors, key risks, win themes and
deal-breakers, each with a verbatim quote and the exact PDF page it came from. It
scores the opportunity against your company profile, tells you whether to bid as
prime or sub, and ranks teaming partners who could close your gaps.
Open the AI analysis in FedSift →
Free forever plan — no credit card.
Browse solicitations without an account; sign in for AI analysis and matching.
Other open solicitations in NAICS 238220
- Backflow Preventer UpgradesDEPT OF DEFENSE · Due 14 September 2026
- B40 Heat pump ReplacementDEPT OF DEFENSE · Due 14 September 2026
- Y1DA--556-26-2-6953-0001 - 556-24-108 Double Block and Bleed Construction (VA-26-00035322)VETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- Y1DA--556-26-2-6953-0001 - 556-24-108 Double Block and Bleed Construction (VA-26-00035322)VETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- Z1DA--CON-NRM-668-26-103S Pharmacy Cache HVAC RepairVETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- FEMA Region 2 Naval Weapons Station Earle Building C-54 HVAC Rooftop Units Replacement and Mini Split Units for Server Room & WarehouseHOMELAND SECURITY, DEPARTMENT OF · Due 14 September 2026
- Inspect, test, repair, maintain, and ensure the operational readiness of all existing fire alarm systems, fire extinguishers, and backflow…COMMERCE, DEPARTMENT OF · Due 14 September 2026
- Z--WY-JACKSON NFH-GEOTHERMAL HVAC RPLCMNTINTERIOR, DEPARTMENT OF THE · Due 14 September 2026
All NAICS 238220 solicitations →
More from AGRICULTURE, DEPARTMENT OF
All AGRICULTURE, DEPARTMENT OF solicitations →
Source: this notice on SAM.gov.
FedSift republishes public federal procurement data and is not affiliated with
the U.S. Government. Always confirm dates and requirements against SAM.gov
before responding.