VLF Voltage Testing

DEPT OF DEFENSE · Solicitation FA6712VoltageTestingVLF · NAICS 541380 · Small Business Set Aside - Total · Closed

Solicitation details

Solicitation numberFA6712VoltageTestingVLF
Notice IDc1e53f2920fb4247be217f732a063f95
AgencyDEPT OF DEFENSE
Sub-tierDEPT OF THE AIR FORCE
Contracting officeFA6712 911 AW LGC
NAICS code541380
Product / service code (PSC)H299
Set-asideSmall Business Set Aside - Total
Notice typeSources Sought
Posted28 July 2026
Response deadline06 August 2026 (closed)
Place of performancePA, USA

Description

SOURCES SOUGHT NOTICE Project Title: VLF Testing of Medium Voltage Power Lines Location: 911th Air Force Reserve Base / Pittsburgh Air Reserve Station (ARS) Notice Type: Sources Sought / Request for Information (RFI) 1. Introduction This Sources Sought notice is being posted in accordance with Request for Offers (RFO) procedures and Federal Acquisition Regulation (FAR) Part 10, Market Research, requirements. This is a Request for Information (RFI) ONLY to conduct market research and determine the availability and technical capability of qualified businesses to provide the required services. This is NOT a solicitation for proposals, proposal abstracts, or quotations. The Government does not intend to award a contract on the basis of this Sources Sought notice or to otherwise pay for the information solicited. 2. Project Description The 911th Air Force Reserve Base (Pittsburgh ARS) is seeking capable and qualified contractors to provide all materials, labor, and equipment necessary to perform Very Low Frequency (VLF) Testing of Medium Voltage Power Lines. The primary objective is to verify the integrity and insulation strength of the designated power lines to ensure safe and reliable operation. There are an estimated 75 locations that will need to be tested on base. Key work elements include, but are not limited to: Developing and executing a comprehensive VLF testing plan demonstrating that the system meets or exceeds IEEE 400.2 standards. Conducting site surveys, equipment preparation, and Lockout/Tagout (LOTO) procedures. Performing VLF testing (0.01 Hz to 0.1 Hz) and insulation resistance testing (IAW IEEE 43). Isolating circuits, identifying potential insulation weaknesses, and resolving defects (repair or replace damaged equipment). Providing a comprehensive report in digital spreadsheet format outlining test results, leakage current readings, defect records, and definitive Pass/Fail determinations. The anticipated Period of Performance is 300 days from the Notice to Proceed (NTP). 3. Contractor must follow these Requirements All installation, testing, and materials must be completed by qualified personnel certified in VLF testing and medium voltage cable testing. Work must be performed in accordance with the latest versions of applicable standards, including: DoD Unified Facility Criteria (UFC) (that we can provide) Air Force Engineering Technical Letters (that we can provide) National Fire Protection (NFPA-70, NFPA-70B) Institute of Electrical and Electronics Engineers (IEEE 400.2, 400-2012, IEEE 43) International Electrical Testing Association (NETA) State and Federal OSHA regulations Contractors must also comply with base access requirements, including background checks for passes and Commercial Vehicle Inspections. 4. Requested Information (Capability Statement) Interested parties are requested to submit a Capability Statement addressing the following: Company Profile: Company name, address, Point of Contact (POC), phone number, email, CAGE Code, and Unique Entity ID (UEI). Socio-Economic Status: Specify any applicable small business classifications (e.g., 8(a), HUBZone, Service-Disabled Veteran-Owned, Women-Owned). Technical Capability: A brief statement detailing your company's ability to perform the VLF testing as described, including the capability to service the estimated 75 locations within the 300-day performance period. Certifications: Confirmation that personnel are properly trained and hold necessary VLF and medium voltage testing certifications. Past Performance: Brief examples of similar work performed in the past three (3) years, preferably on military installations or large commercial facilities. 5. Submission Instructions All responses to this Sources Sought notice must be submitted electronically to the Contracting Office via email at Ryan.Scott.34@us.af.mil and Crystal.Spurlin@us.af.mil no later than 12:00 PM on 08/6/2026. Please include "Sources Sought Response: VLF Testing - Company Name and CAGE CODE" in the subject line. Disclaimer: Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions.

Go deeper on this solicitation

FedSift reads the full solicitation package — every attachment — and pre-extracts the compliance matrix, evaluation factors, key risks, win themes and deal-breakers, each with a verbatim quote and the exact PDF page it came from. It scores the opportunity against your company profile, tells you whether to bid as prime or sub, and ranks teaming partners who could close your gaps.

Open the AI analysis in FedSift →

Free forever plan — no credit card. Browse solicitations without an account; sign in for AI analysis and matching.

Other open solicitations in NAICS 541380

All NAICS 541380 solicitations →

More from DEPT OF DEFENSE

All DEPT OF DEFENSE solicitations →

Source: this notice on SAM.gov. FedSift republishes public federal procurement data and is not affiliated with the U.S. Government. Always confirm dates and requirements against SAM.gov before responding.