Solicitations
› VETERANS AFFAIRS, DEPARTMENT OF
› NAICS 238220
J045--NOTICE OF INTENT TO SOLE TO DAIKIN APPLIED AMERICAS INC FOR VFD REPLACEMENT ON A DAIKIN CHILLER WASHINGTON DC VA MEDICAL CENTER 36C24526Q0645
VETERANS AFFAIRS, DEPARTMENT OF · Solicitation 36C24526Q0645 · NAICS 238220 · Unrestricted (full and open) · Closed
This solicitation has closed.
Responses were due 21 July 2026.
The record stays published because closed procurements are what a recompete is
built from — the follow-on is typically solicited 6–18 months before the
incumbent contract ends. Open solicitations like this one are linked below.
Solicitation details
| Solicitation number | 36C24526Q0645 |
|---|
| Notice ID | e4efcae4be0940ee9b46cccb18615bc6 |
|---|
| Agency | VETERANS AFFAIRS, DEPARTMENT OF |
|---|
| Sub-tier | VETERANS AFFAIRS, DEPARTMENT OF |
|---|
| Contracting office | 245-NETWORK CONTRACT OFFICE 5 (36C245) |
|---|
| NAICS code | 238220 |
|---|
| Product / service code (PSC) | J045 |
|---|
| Set-aside | Unrestricted (full and open) |
|---|
| Notice type | Special Notice |
|---|
| Posted | 08 July 2026 |
|---|
| Response deadline | 21 July 2026 (closed) |
|---|
| Competition | Sole source — not open to competitive bidding |
|---|
Description
SUMMARY: Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5, is issuing this NOTICE OF INTENT TO SOLE SOURCE TO Daikin Applied Americas, Inc. to replace a Variable Frequency Drive (VFD) on Daikin WSC 087 Centrifugal Chiller, Serial No. STNU110700045. All responsible sources may submit a capabilities statement and a proposal for consideration. All responses must include the following information or will not be considered. Please respond to this intent to sole sources notice 36C24526Q0645 with your: 1. Business name (including Unique Entity ID (SAM.gov) 2. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned, Disadvantaged Small Business, 8(a), etc.), and 3. Person of contact (including telephone number & email address). 4. Capability statement and summary of previous experience providing these types of services for the Veterans Health Administration or other similar facilities. 5. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (include applicable NAICS) 6. Brief Summary of categories of services that your company can/cannot provide. 7. Certification(s) / Licenses for meeting the local requirements to provide these services at the DC VAMC (if applicable) 8. Confirmation that your organization has the capability & expertise to meet the performance requirements while complying with applicable limitations in subcontracting by responding to the questions below with your response: a. Do you intend to self-perform this effort? b. If you are located outside the immediate area, how will you self-perform? c. Or do you intend to subcontract work under this contract? d. If you intend to subcontract work under this contract, how will you ensure compliance with the limitations on subcontracting? Also, your written proposal and certifications demonstrate competency. This notice of intent is not a request for competitive quotations. The Government is under no obligation to consider or make an award to any respondent that submits a capability statement or proposal. Responses received will be considered solely for the purpose of determining whether to conduct a competitive procurement. The Department of Veterans Affairs is not required to award based on any submissions received. Respond with all information by July 17th, 2026 at 08:00 AM ET. Send all responses to Bill Pratt. Billie.Pratt@va.gov See Statement of Work Next Page. STATEMENT OF WORK Research Chiller Variable Frequency Drive (VFD) Upgrade DC VA Medical Center Facility Washington DC VA Medical Center, 50 Irving St NW, Washington, DC 20422 Requesting Office Facilities Management Service (FMS) Equipment Daikin WSC 087 Centrifugal Chiller, Serial No. STNU110700045 1. BACKGROUND The Washington DC VA Medical Center (VAMC) operates a Daikin WSC 087 centrifugal chiller (Serial No. STNU110700045) within its Research Building central plant. This chiller provides critical cooling to research laboratory spaces where climate control is essential for patient safety research and specimen integrity. The existing variable frequency drive (VFD) and motor starter on this unit have experienced degraded performance and are approaching end of serviceable life, creating risk of unplanned system failure. Daikin Applied Americas, Inc. is the original equipment manufacturer (OEM) for this chiller and the exclusive authorized source for factory-engineered VFD upgrade kits compatible with the WSC 087 platform. The proposed upgrade replaces the VFD power box assembly and associated wiring with Daikin's current-generation VFD, restoring reliability and extending equipment lifespan without requiring a full chiller replacement. 2. SCOPE OF WORK The contractor shall provide all parts, labor, supervision, tools, equipment, software upgrades, and testing necessary to complete a full VFD upgrade on the Daikin WSC 087 centrifugal chiller at the DC VAMC Research Building. The work consists of three primary phases: 2.1 Upgraded Parts Supply The contractor shall furnish and deliver the following OEM replacement components: VFD Power Box Assembly (Daikin factory-engineered for WSC 087 platform) All interconnecting wire harnesses between the VFD and chiller controls module All associated mounting hardware, fasteners, and cabling required for a complete installation 2.2 Labor and Installation The contractor shall perform the following installation tasks in accordance with Daikin's published service procedures and all applicable safety requirements: Coordinate with the VA COR and FMS to schedule work during an approved maintenance window that minimizes disruption to Research Building operations. Isolate the chiller from all electrical sources and implement a Lockout/Tagout (LOTO) procedure in accordance with 29 CFR 1910.147 and VA facility safety protocols prior to commencing any work. Assemble and position appropriate rigging and lifting equipment as required by the physical configuration of the chiller room. All rigging activities shall comply with OSHA standards. Remove and properly dispose of the existing VFD and motor starter assembly in accordance with applicable regulations. Rig and transport the new VFD cabinet to the chiller location. Fabricate a new mounting assembly for the VFD cabinet if the existing mounting structure is not compatible with the replacement unit. Install the new VFD cabinet and connect all wiring per manufacturer specifications. Supply and install all hardware, conduit, and cabling associated with the VFD installation. 2.3 Testing, Startup, and Commissioning Upon completion of installation, the contractor shall: Execute all required chiller control software upgrades to ensure compatibility with the new VFD. Conduct a functional run test to verify proper VFD operation, chiller response, and control system integration. Initiate the system startup sequence and perform all final calibrations in accordance with Daikin startup procedures. Generate and provide to the VA COR a complete commissioning report documenting startup readings, calibration data, and test results. 4. PLACE OF PERFORMANCE All work shall be performed on-site at: Washington DC VA Medical Center 50 Irving Street NW Washington, DC 20422 Research Building Central Plant specific chiller room location to be confirmed with FMS prior to mobilization.
Go deeper on this solicitation
FedSift reads the full solicitation package — every attachment — and pre-extracts
the compliance matrix, evaluation factors, key risks, win themes and
deal-breakers, each with a verbatim quote and the exact PDF page it came from. It
scores the opportunity against your company profile, tells you whether to bid as
prime or sub, and ranks teaming partners who could close your gaps.
Open the AI analysis in FedSift →
Free forever plan — no credit card.
Browse solicitations without an account; sign in for AI analysis and matching.
Other open solicitations in NAICS 238220
- Backflow Preventer UpgradesDEPT OF DEFENSE · Due 14 September 2026
- B40 Heat pump ReplacementDEPT OF DEFENSE · Due 14 September 2026
- Y1DA--556-26-2-6953-0001 - 556-24-108 Double Block and Bleed Construction (VA-26-00035322)VETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- Y1DA--556-26-2-6953-0001 - 556-24-108 Double Block and Bleed Construction (VA-26-00035322)VETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- Z1DA--CON-NRM-668-26-103S Pharmacy Cache HVAC RepairVETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- FEMA Region 2 Naval Weapons Station Earle Building C-54 HVAC Rooftop Units Replacement and Mini Split Units for Server Room & WarehouseHOMELAND SECURITY, DEPARTMENT OF · Due 14 September 2026
- Inspect, test, repair, maintain, and ensure the operational readiness of all existing fire alarm systems, fire extinguishers, and backflow…COMMERCE, DEPARTMENT OF · Due 14 September 2026
- Z--WY-JACKSON NFH-GEOTHERMAL HVAC RPLCMNTINTERIOR, DEPARTMENT OF THE · Due 14 September 2026
All NAICS 238220 solicitations →
More from VETERANS AFFAIRS, DEPARTMENT OF
- 6640--Albany VAMC PLMS MALDI NEW CONTRACT FY 27 (VA-27-00006444)VETERANS AFFAIRS, DEPARTMENT OF · Due 13 September 2026
- Fort Sam Houston National Cemetery Tree Pruning Cascading EvaluationVETERANS AFFAIRS, DEPARTMENT OF · Due 13 September 2026
- Cardio-Pulmonary BoomsVETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- 6835-- BULK OXYGEN (Base+4 Option)VETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- Specimen Barcode Software Iowa City VAVETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- Dental Imaging Equipment- CS 9600, Radiographic Units, and sensor kitsVETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- Dental Imaging Equipment- CS 9600, Radiographic Units, and sensor kitsVETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- NEUROFORTIS NEUROSMART DRIVE HEADSTAGE KITVETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
All VETERANS AFFAIRS, DEPARTMENT OF solicitations →
Source: this notice on SAM.gov.
FedSift republishes public federal procurement data and is not affiliated with
the U.S. Government. Always confirm dates and requirements against SAM.gov
before responding.