Solicitations
› INTERIOR, DEPARTMENT OF THE
› NAICS 238220
Z--HVAC Replacement at Planet Ranch Conservation Area (PRCA).
INTERIOR, DEPARTMENT OF THE · Solicitation DOIRFBO260011 · NAICS 238220 · Unrestricted (full and open) · Closed
This solicitation has closed.
Responses were due 27 July 2026.
The record stays published because closed procurements are what a recompete is
built from — the follow-on is typically solicited 6–18 months before the
incumbent contract ends. Open solicitations like this one are linked below.
Solicitation details
| Solicitation number | DOIRFBO260011 |
|---|
| Notice ID | b43ce9ee6c5a41c49e8f7ad5f32911ec |
|---|
| Agency | INTERIOR, DEPARTMENT OF THE |
|---|
| Sub-tier | BUREAU OF RECLAMATION |
|---|
| Contracting office | LOWER COLORADO REGIONAL OFFICE |
|---|
| NAICS code | 238220 |
|---|
| Product / service code (PSC) | Z2FZ |
|---|
| Set-aside | Unrestricted (full and open) |
|---|
| Notice type | Sources Sought |
|---|
| Posted | 09 July 2026 |
|---|
| Response deadline | 27 July 2026 (closed) |
|---|
Description
This is a Sources Sought announcement for acquisition planning purposes and no formal solicitation for this requirement exists at this time. All businesses, regardless of size; capable of providing these services, are invited to respond to this announcement and submit a capability statement for consideration. Capability statements received will be reviewed to determine a firm's previous experience performing similar work and used to determine an appropriate procurement strategy, in particular, whether a small business set-aside is warranted or an alternate procurement strategy. The Government does not intend to award a contract on the basis of this notice or otherwise pay for information solicited. Proposed Project: The Bureau of Reclamation (Reclamation), Lower Colorado Basin, Multi-Species Conservation Program (MSCP), has a requirement to replace two existing HVAC systems on two bunk houses at Planet Ranch Conservation Area (PRCA). PRCA is located in a remote area outside of Parker, Arizona along the Bill Williams River. Access to the site is via an unpaved, sometimes primitive road that may be affected by weather and local conditions. Contractors should plan accordingly for transportation of personnel, materials, and equipment. Building 1 is approximately 3,000 square feet and Building 2 is approximately 2,400 square feet. Both buildings are single story houses. To support onsite work, contractors will have the option to stay in the existing bunk houses for the duration of the HVAC replacement activities. Government-furnished heavy equipment, including a telehandler, will be available onsite for use in removing the two existing HVAC units from the roof. This equipment may be used by the contractor in accordance with Reclamation's standards for government-furnished property. Principal components of work are as follows: 1. Removal and disposal of the two existing roofs mounted electric dual heating and air-conditioning units. 2. Roof repairs will include, but are not limited to the replacement of plywood, weather shielding, underlayment, and shingles. 3. Purchase and deliver two new ground mounted electric dual heat and air-conditioning units. 4. Placement of steel reinforcement and concrete pads for ground mounted air-conditioning units. Ground mounted units must include installation of new electrical, ductwork, and air handlers placed inside the residential buildings. All ductworks shall be insulated and metal to reduce pest intrusion. 5. The installation of new thermostat systems in each of the residential buildings that is compatible with the new HVAC systems if required. 6. Testing and analysis of the replacement system to determine that the systems are functioning properly. The applicable North American Industry Classification System (NAICS) Code 238220, Plumbing, Heating, and Air-Conditioning Contractors with a corresponding small business size standard of $19M. Interested firms are requested to submit the following information: 1. Name and address of Firm 2. Phone number 3. Email Address 4. Unique Entity ID (formerly DUNS Number) 5. Size status/SBA certifications (Small business, Women Owned Small Business, HUBZone, Service-Disabled Veteran Owned Small Business, other) 6. Capability Statement (not to exceed 10 pages). A brief summary of capabilities to include demonstration of the firm's capability to perform the work. Previous procurements performed of similar size and complexity to include references with point of contact information. All responses must be submitted via email no later than 2:00 P.M., Pacific Time, July 27, 2026. Email address: diane_rodriguez@ios-doi.gov. Include the reference number (DOIRFBO26011) in the subject line. All questions concerning the sources sought announcement should be directed to Diane Rodriguez by email at diane_rodriguez@ios.doi.gov. No phone calls please. When it is determined that a formal solicitation will be issued, the pre-solicitation notice will be posted on Contract Opportunities at sam.gov web site at http://sam.gov/.
Go deeper on this solicitation
FedSift reads the full solicitation package — every attachment — and pre-extracts
the compliance matrix, evaluation factors, key risks, win themes and
deal-breakers, each with a verbatim quote and the exact PDF page it came from. It
scores the opportunity against your company profile, tells you whether to bid as
prime or sub, and ranks teaming partners who could close your gaps.
Open the AI analysis in FedSift →
Free forever plan — no credit card.
Browse solicitations without an account; sign in for AI analysis and matching.
Other open solicitations in NAICS 238220
- Backflow Preventer UpgradesDEPT OF DEFENSE · Due 14 September 2026
- B40 Heat pump ReplacementDEPT OF DEFENSE · Due 14 September 2026
- Y1DA--556-26-2-6953-0001 - 556-24-108 Double Block and Bleed Construction (VA-26-00035322)VETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- Y1DA--556-26-2-6953-0001 - 556-24-108 Double Block and Bleed Construction (VA-26-00035322)VETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- Z1DA--CON-NRM-668-26-103S Pharmacy Cache HVAC RepairVETERANS AFFAIRS, DEPARTMENT OF · Due 14 September 2026
- FEMA Region 2 Naval Weapons Station Earle Building C-54 HVAC Rooftop Units Replacement and Mini Split Units for Server Room & WarehouseHOMELAND SECURITY, DEPARTMENT OF · Due 14 September 2026
- Inspect, test, repair, maintain, and ensure the operational readiness of all existing fire alarm systems, fire extinguishers, and backflow…COMMERCE, DEPARTMENT OF · Due 14 September 2026
- Z--WY-JACKSON NFH-GEOTHERMAL HVAC RPLCMNTINTERIOR, DEPARTMENT OF THE · Due 14 September 2026
All NAICS 238220 solicitations →
More from INTERIOR, DEPARTMENT OF THE
- EAFM UTV'SINTERIOR, DEPARTMENT OF THE · Due 12 September 2026
- 23--Special Notice of Intent to Award A sole Source ContractINTERIOR, DEPARTMENT OF THE · Due 12 September 2026
- HAVO Eruption Debris Clean UpINTERIOR, DEPARTMENT OF THE · Due 13 September 2026
- D--Network Connectivity Fiber Network BackboneINTERIOR, DEPARTMENT OF THE · Due 14 September 2026
- 47--2026 NM RANGE SUPPLYINTERIOR, DEPARTMENT OF THE · Due 14 September 2026
- 7A--FILE360 SOFTWARE & MICROGRAPHIC HARDWAREINTERIOR, DEPARTMENT OF THE · Due 14 September 2026
- D--Notice of Intent to Sole SourceINTERIOR, DEPARTMENT OF THE · Due 14 September 2026
- Shallow Water Boat, Motor, & TrailerINTERIOR, DEPARTMENT OF THE · Due 14 September 2026
All INTERIOR, DEPARTMENT OF THE solicitations →
Source: this notice on SAM.gov.
FedSift republishes public federal procurement data and is not affiliated with
the U.S. Government. Always confirm dates and requirements against SAM.gov
before responding.