J041--TVHS VFD Replacement

Inactive on SAM.gov — responses were due 16 Jun 2026 · Service-Disabled Veteran-Owned Small Business Set Aside · Department of Veterans Affairs (VA) · Nashville · NAICS 238220 · Solicitation 36C24926Q0229

Following NAICS 238220? Get new solicitations in it by email as they post — no account needed.

Email me new ones

A newer version of this notice has been posted. SAM.gov republished solicitation 36C24926Q0229 on 23 July 2026. This page is kept because it is a real record, but the current requirement, dates and attachments are on the latest version. Read the latest version →

What happened next

SAM.gov marked this notice inactive — responses were due 16 June 2026.

No award notice on SAM.gov yet. Not every award is posted there, so this does not mean it went unawarded.

Email me when the award is announced. One email, when SAM.gov posts the award notice. Not every award is posted there; if none appears within six months we'll tell you and stop. No account needed.

Solicitation details

Solicitation number36C24926Q0229
Notice IDbf3491b232124b02882b8d875113f26a
AgencyDepartment of Veterans Affairs (VA)
Contracting office249-NETWORK CONTRACT OFFICE 9 (36C249)
NAICS code238220 — Plumbing, Heating, and Air-Conditioning Contractors
Product / service code (PSC)J041
Set-asideService-Disabled Veteran-Owned Small Business Set Aside
Notice typeCombined Synopsis/Solicitation
Posted04 June 2026
Response deadline16 June 2026 (closed)
Place of performanceNashville

Get new NAICS 238220 solicitations by email

This one has closed. We'll email you when new NAICS 238220 (Plumbing, Heating, and Air-Conditioning Contractors) solicitations post — the first email lists what is open right now, then at most once a week, only when something new posts. No account needed; unsubscribe in a click.

Description

The purpose of this amendment is to post Questions and Answers to Solicitation 36C24926Q0229 TVHS VFD Replacements Questions and Answers 36C24926Q0229 VFD Replacements Question: Is this is a brand new contract OR if there is (was) an incumbent performing these services. Answer: This is a new contract Question: Is there a scheduled site visit or if one can be arranged? We would appreciate any details you could provide, including the date and time, if applicable. Answer: Site visit will be scheduled and no pictures will be provided. Email Stephen.Browne@va.gov to set up a site visit. Question: Specification Section 5.b requires NICET Level I or NETA Level II certification. Will the Government accept licensed electricians and manufacturer-certified VFD/controls technicians as an equivalent qualification? Answer: Because this a replacement and the systems are tied to the Fire system. You would need electricians and manufacturer-certified VFD/controls technicians as an equivalent qualification? Question: Please confirm whether electrical one-lines, mechanical and electrical plans, existing VFD schedules, control diagrams, BAS point lists, fire alarm interface diagrams, or record/as-built drawings are available for the listed VFD locations. If available, please provide them with amendment. Answer: Because this a replacement we can provide locations and point lists, upon request Question: Please confirm whether photos of the existing VFDs, disconnects, bypasses, conduit entries, mounting locations, BAS/control panels, and related fan room and mechanical room conditions can be provided by amendment. Answer: Because this a replacement we can provide locations and pictures upon request Question: Please confirm whether the Government will schedule a pre-bid site visit or escorted field verification before the quote due date so vendors can review existing VFD locations, mounting conditions, access, conduit entries, control interfaces, and outage constraints. Answer: Outage constraints can be worked by scheduling after contract is awarded. We can set up a pre bid site visit if needed. (See Question 2) Question: The SOW states the facility standard is Danfoss and the technical evaluation subfactor requires Danfoss-manufactured VFDs. Please identify the required Danfoss model, series, or product line and any required options or accessories. Answer: The Danfoss model series would be determined by the size required for the equipment Question: The equipment list specifies a disconnect with bypass for each unit. Please clarify whether the bypass is required to be an integral VFD bypass package, a separate disconnect and bypass assembly, or another specific VA-standard configuration. Answer: Some of the VFDs being replaced are standalone VFDs, these require build in bypass and disconnect. Others are dual systems with added cabinets with disconnects and contactors as interlocks so only one can run at a time. Question: Please provide or clarify the required BAS point list, communication protocol, graphics requirements, trend requirements, alarm requirements, and sequence updates for each VFD. Answer: Because this a replacement we can provide locations and point lists, upon request Question: Please identify which listed VFDs, AHUs, fans, or pumps require fire alarm interface, shutdown, monitoring, or sequence integration. If available, please provide fire alarm drawings or sequence documentation by amendment. Answer: Only supply and returns for AHUs and some exhaust fans FR 3 AHU 9 Supply 1 133129 40 FR 3 AHU 9 Return 1 90770 10 FR 3 AHU 9 Return 2 98773 10 FR 1 AHU 5 Supply 1 96487 40 FR 1 AHU 5 Supply 2 96486 40 FR 17 AHU 54 No # 25 FR 17 RF 54 A No # 5 FR 17 RF 54 b No # 5 FR 10 AHU 33 99076 25 FR 4 AHU 22 No # 15 FR 4 RF 22 No # 7.5 FR 11 AHU 26 90743 40 F-8 RF 31 116838 7.5 FR 10 EF72 123027 1.5 FR 10 EF55 123024 2 FR 10 EF64 123023 20 FR 12 AHU 4 No # 5 FR 3 Tertiary Pump 33694 15 F-8 HWP 6 No # 5 FR 9 AHU 32 99075 30 FR 16 AHU 52 Supply 88170 40 FR 16 AHU 52 Return 88174 5 FR 16 AHU 51 Supply 88171 40 FR 16 AHU 51 Return 88175 5 Question: Please clarify whether any of the listed AHUs, return fans, exhaust fans, or pumps are part of a smoke control or other life safety sequence that requires special testing, witnessing, or documentation. Answer: Only the AHUs Question: Please identify any listed equipment serving critical, sensitive, or restricted hospital areas and any outage limitations beyond the general after-hours and weekend coordination requirement. Answer: AHU 54 would have to be scheduled for after-hours Question: Please clarify whether the Government requires witnessed functional testing for each VFD, BAS point verification, bypass testing, fire alarm interface testing, or other commissioning checkpoints. Answer: Yes, this part of commissioning Question: Please clarify available loading and unloading areas, freight or service elevator access if applicable, staging limitations, parking limitations, and whether work areas require special access procedures beyond standard badging. Answer: Contractor parking is available. Contractors for this project will be escorted by VA personnel. Question: Please confirm whether one qualified prime contractor employee may serve in multiple project roles, such as Superintendent, Site Safety and Health Officer, Quality Control Manager, and Project Manager, provided that the individual meets all applicable qualification requirements and can properly perform each required function for the project. Answer: Provided that this person is onsite during installation.

Version history

SAM.gov has posted 4 notices under solicitation 36C24926Q0229, oldest first.

Go deeper on this solicitation

FedSift reads the full solicitation package — every attachment — and pre-extracts the compliance matrix, evaluation factors, key risks, win themes and deal-breakers, each with a verbatim quote and the exact PDF page it came from. It scores the opportunity against your company profile, tells you whether to bid as prime or sub, and ranks teaming partners who could close your gaps.

Open the AI analysis in FedSift →

Free forever plan — no credit card. Browse solicitations without an account; sign in for AI analysis and matching.

Market context: VA and NAICS 238220

About the buyer and the industry, not this specific solicitation. Source: USASpending.gov award data, updated nightly.

  • In fiscal year 2026, VA obligated $311.6M across 692 contract actions under NAICS 238220.
  • 318 contracts worth $471.7M in this category end within the next 18 months.

VA contracts under NAICS 238220 →

Other open solicitations in NAICS 238220

All NAICS 238220 solicitations →

More from Department of Veterans Affairs

All VA solicitations →

Source: this notice on SAM.gov. FedSift republishes public federal procurement data and is not affiliated with the U.S. Government. Always confirm dates and requirements against SAM.gov before responding.

FedSift turns SAM.gov and USASpending data into federal BD intelligence — smart matches, recompete radar, cited AI solicitation analysis and compliance matrices.

Source data: SAM.gov (solicitations) and USASpending.gov (awards), refreshed nightly. FedSift is not affiliated with the U.S. Government.

Pricing · Privacy · Terms · support@fedsift.app